- 58 -
Symptom
Check Point
1. Water mode
doesn’t work
1. Check the loose connection
2. Check the resistance valve
Water Valve
Pilot Valve
Resistance [Ω]
Pilot Valve
360~420
Water valve
360~420
CON2
CON2
LEVER S/W
Voltage [V]
CON2
11
th
pin ~
B(NEUTRAL)
Pushing
112~115V
Not
Pushing
0~2V
CON2
10
th
pin ~
B(NEUTRAL)
Pushing
112~115V
Not
Pushing
0~2V