- 36 -
CON7
CN1
CON201
CON2
CON1
CON3
CON5
CON6
Symptom
Check Point
1. r dS
1. Check for a loose connection
2. Check Sensor Resistance
Resistance [Ω]
CON7
13
th
pin ~ 14
th
pin
Short
0
Open
OFF
Other
Normal
CON7
13
th
pin ~ 14
th
pin
Resistance [Ω]
23ºF / -5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
Defrost Controller
CON7
8-5. Defrost Sensor Error (r dS)
Содержание 795.74092.41 Series
Страница 7: ... 7 ...
Страница 23: ... 23 5 CIRCUIT DIAGRAM ...
Страница 24: ... 24 6 TROUBLESHOOTING ...
Страница 25: ... 25 ...
Страница 27: ... 27 7 3 Sub PCB P N EBR76468402 ...
Страница 103: ...625A 623B 616J 623B 616J 603C S04 627B S04 627A S04 603B 619A 617A 616G VALVE WATER TUBE PARTS ...
Страница 105: ...CASE PARTS ...
Страница 106: ...CASE PARTS ...
Страница 110: ...DOOR PARTS ...
Страница 111: ...DISPENSER PARTS 405A 278D 402C 276B 275A 276A 276I 501A 279A 278B 500J 276J 267B 279J 281A ...
Страница 112: ...ICE MAKER ICE BIN PARTS 600A 630F 630B 630A 630H 630G 630C 630Q 630E 630D 611A 612A 630J 606A 630J 607A ...