INSTALLATION INSTRUCTIONS
Install the shutoff valve on the nearest frequently used
drinking water line.
1. SHUT OFF THE MAIN WATER SUPPLY
Turn on the nearest faucet to relieve the pressure on
the line.
2. CHOOSE THE VALVE LOCATION
Choose a location for the valve
that is easily accessible. It is best
to connect into the side of a
vertical water pipe. When it is
necessary to connect into a
horizontal water pipe, make the
connection to the top or side,
rather than at the bottom, to avoid
drawing off any sediment from the water pipe.
3. DRILL THE HOLE FOR THE VALVE
Drill a 1/4" hole in the water
pipe using a sharp bit.
Remove any burrs resulting
from drilling the hole in the
pipe. Take care not to allow
water to drain into the drill.
Failure to drill a 1/4" hole
may result in reduced ice production or smaller cubes.
NOTE:
The hookup line cannot be white, plastic
tubing. Licensed plumbers must use only copper
tubing NDA tubing #49595 or 49599 or Cross Link
Polyethylene(PEX) tubing.
4. FASTEN THE SHUTOFF VALVE
Fasten the shutoff valve to the cold water pipe with
the pipe clamp.
NOTE:
Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
5. TIGHTEN THE PIPE CLAMP
Tighten the clamp screws until the sealing washer
begins to swell.
NOTE:
Do not overtighten or you may crush the tubing.
6. ROUTE THE TUBING
Route the tubing between the cold water line and the
refrigerator.
Route the tubing through a hole drilled in the wall or
floor (behind the refrigerator or adjacent base cabinet)
as close to the wall as possible.
NOTE:
Be sure there is sufficient extra tubing (about
8 feet coiled into 3 turns of about 10" diameter) to
allow the refrigerator to move out from the wall after
installation.
7. CONNECT THE TUBING TO THE VALVE
Place the compression nut and ferrule (sleeve)
for copper tubing onto the end of the tubing and
connect it to the shutoff valve. Make sure the tubing is
fully inserted into the valve. Tighten the compression
nut securely.
NOTE:
Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
CONNECTING THE WATER LINE
31
Pipe Clamp
Vertical Cold
Water Pipe
Saddle-Type
Shutoff Valve
Saddle-Type
Shutoff Valve
Ferrule (sleeve)
Compression Nut
Packing Nut
Outlet Valve
Pipe Clamp
Inlet End
Washer
Clamp Screw