Kenmore 79078502010 Скачать руководство пользователя страница 1

Содержание 79078502010

Страница 1: ...id and level Refer to your serial plate for applicable agency certifications Provide Proper Fuel Type Provide proper fuel type Before proceeding You r range is factory preset to operate on natural gas If LP conversion is needed contact your local LP Gas provider for assistance The LP conversion kit may be located on the lower rear back panel of the range If no LP kit is provided contact your produ...

Страница 2: ...oor covering can withstand heat at least 90 F above room temperature without shrinking warping or discoloring Do not installthe range over carpeting unless you place an insulating pad or sheet of 1 4 inch thick plywood between the range and carpeting Make sure the wall coverings around the range can withstand the heat generated by the range Do not obstruct the flow of combustion air at the oven ve...

Страница 3: ...g tape Fig 14 Pipe joint sealant that resists action of LP Propane gas Fig 15 Gas line manual shut off valve Fig 16 1 2 NPT 90 black pipe elbow Fig 17 A new flexible metal appliance conduit 1 2 NPT x 3 4 or 1 2 I D must be design certified by CSA International Fig 18 Because solid pipe restricts moving the range we recommend using a new flexible conduit 48 MAXIMUM LENGTH for each new installation ...

Страница 4: ...m Minimum on depth for cabinets either side of above ramge top 30 Cabinet Opening width Back Wall Fig A Back Wall Fig B Install a flush mount 240V 40 50 ampere electrical wall outlet in the shaded area Do not seal the range to side cabinets Do not pinch the power supply cord between the range and the wall If cabinet depth is greater than 25 the oven front frame must extend beyond cabinet front by ...

Страница 5: ...llow the bracket to fit flush against wall remove molding or mount bracket to floor For wall mount Fig 24 locate the bracket by placing the back edge of the template against rear wall and the side edge of template on the mark made referencing the side of the range Place bracket on top of template and mark location of the screw holes in wall If rear of range is further than 1 1 4 from wall when ins...

Страница 6: ...ent Excess wire inthe range compartment may not allow the access cover to be replaced properly and could create a potential electrical hazard if wires become pinched Connect only as instructed under WIRING INSTRUCTIONS in Step Bof the Installation Steps When using flexibleconduit or range cable use flex connector or range cable strain relief See Fig 32 on page 7 NOTE Only usecopper wire in connect...

Страница 7: ...home requires 4 Wire connection Power cord instructions 1 Followthemanufacturer sinstallationinstructions supplied with the strain relief and install Also see Figs 29 30 31 32 2 Insert the end connectors for Line 1 Line 2 and Neutral and tighten securely to the terminal block IMPORTANT NOTE DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block Elec...

Страница 8: ...a separate ground wire must be connected to the separate ground screw attached to the range chassis and to an adequate ground source For 3 4 Wire permanent connections ONLY 3 Wire permanent connection follow Steps 1 2 5 below 4 Wire permanent connection follow Steps 1 thru 5 below Before wiring the range review the suggested power source location drawings in Fig A B If connecting to a 4 Wire elect...

Страница 9: ... from frame of the appliance Cut and discard the copper strap from the terminal block KEEP the ground screw ground plate and go to Step 4 4 4 Wire Permanent Connection ONLY Connectthe ground wire lead Green to the frame of the appliance using the ground screw plate as shown in Fig 36 Be sure to install using the same hole in the frame where the ground screw was originally installed 5 3 4 Wire Perm...

Страница 10: ...37 Do not allow the Pressure Regulator to turn on pipe when tightening fittings 4 Attach flexible Appliance Conduit to Flare Adapter on Pressure Regulator Figs 18 37 5 Install 2nd Flare Adapter to external manual Shut Off Valve Figs 19 37 6 Attach flexible Appliance Conduit to Flare Adapter on Shut Off Valve Fig 37 7 After making these connections check for gas leaks Turn the gas supply on to the ...

Страница 11: ...the knob in and turn counterclockwise out of the OFF position See Fig 1 3 Release the knob and rotate to the LITE position Note All electronic surface ignitors will spark at the same time However only the burner you are turning on will ignite 4 Visually check that the burner has lit 5 Push the control knob in and turn counterclockwise to the desired flame size The control knobs do not have to be s...

Страница 12: ...se Care Guide for cleaning instructions If removing the range is necessary for cleaning or maintenance shut off the gas supply Disconnect the gas and electrical supply If the gas or electrical supply is inaccessible lift the range slightly at the front and pull out away from the wall Pull only as far as necessary to disconnect the gas and electrical supply Finish removing the range for servicing a...