background image

Содержание 79075721991

Страница 1: ...IN THE MANUFACTURER S INSTRUCTIONS SUPPLIED WITH THE KIT BEFORE PROCEEDING WITH THE CONVERSION SHUT OFF THE GAS SUPPLY BEFORE DISCONNECTING ELECTRICAL POWER TO THE RANGE BE SURE BOTH POWER SUPPLIES ARE OFF BEFORE INSTALLING THE CONVERSION KIT FAILURE TO DO SO COULD CAUSE SERIOUS BODILY INJURY This kit contains the following Quantity Description Part Number 1 4 4 4 Top Burner Orifice Marked 0 89 mm...

Страница 2: ...nger II II Front Access to Regulator Remove Kick Panel StorageDrawer or Warmer Drawer See Owner s Guide for Instructions If Equipped with Broiler Drawer Open Broiler Drawer Pressure Regulator location at rear of range Left Glide Right Glide _er p__ L FIGURE 1 FIGURE 2 e Do not remove the Pressure Regulator or allow it to rotate or turn Remove the dust protector from the cap Using a 5 8 wrench unsc...

Страница 3: ...e screw A Be sure the screw head is in line with the recess in the choke i Replace burner caps and top grates Burner Cap Screw Choke Restrictor Screw Electrode FIGURE 4 Use caution when replacing the burner cap so the electrode is not damaged 5 8 Burner Flame Size _ _ FIGURE 5 Note Air mixture adjustment not required on top burners 3 Convert Oven Burner Orifice for LP Propane Gas 16 000 BTU a Loca...

Страница 4: ...ush in and turn control to LITE until burner ignites b Push in and auickly turn knob to LOWEST POSITION c If burner goes out reset control to OFF d Remove the surface burner control knob e Insert a thin bladed screwdriver into the hollow valve stem and engage the slotted screw inside Flame size can be increased or decreased with the turn of the screw Turn counterclockwise to increase flame size Tu...

Страница 5: ... baffle and oven bottom H FIGURE 1 1 b If adjustment to the air shutter is necessary locate the broiler bumer air shutter loosen shutter set screw and adjust to obtain optimum flame This will normally be compJetely open for LP Propane gas If the flame is yellow in color increase the air shutter opening size If the flame is a distinct blue but lifting away from the burner reduce the air shutter ope...

Страница 6: ... Convert pressure regulator turn cap over so the solid end of cap faces outward Place the hollow end of the cap into the loop end of the dust protector See step 1 c Replace 89 mm orifices in the top burners with original 1 60 mm orifices Remove the LP Propane restrictor in the cavity directly opposite the electrode Replace screw previously holding restrictor in place Do not over tighten Remove the...

Отзывы: