Страница 1: ...Owner s Manual Manual del Propietario ROOM AIR CONDITIONER ACONDICIONADOR DE AIRE DE VENTANA Model Modelo 580 71121 Sears Roebuck and Co Hoffman Estates IL 6qEWIg_et_ www sears com ...
Страница 2: ...ions in this owner s manual Sears will repair this air conditioner free of charge if defective in material or workmanship FULL FIVE YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase when this air conditioner is operated and maintained for normal room cooling according to instructions in this owner s manual Sears will repair the sealed refrigeration system consis...
Страница 3: ...nding plug for protection against shock hazards Your air conditioner must be plugged into a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with outside protective cover in place This could result in mechani...
Страница 4: ...le shock hazard the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly grounded 3 prong wall receptacle installed by a qualified ele...
Страница 5: ...L for future reference The carton is the best way to store unit during winter or when not in use INSTALLATION HARDWARE FIG 2 ITEM NAME OF PARTS Q TY A SIDE CURTAIN 2 B SILL SUPPORT 2 C BOLT 2 D LOCK NUT 2 E SCREW 25 64 13 F SCREW 5 8 3 G SCREW 5 8 5 H FOAM SEAL 1 I FOAM STRIP 1 J L BRACKET 1 To avoid risk of personal injury property damage or product damage due to the weight of this device and sha...
Страница 6: ...ward while bracing the cabinet FIG 4 _ Tcut the FOAM STRIP ITEM I to fit the underside of the window sash Peel off the backing and attach the FOAM STRIP as shown in Fig 5 _ Insert the side curtain ITEM A into the upper guide and lower guide of the air conditioner Fasten the curtains to the unit with screws ITEM E FIG 6 _J Open the window Mark a line on center of the window inner sill or desired ai...
Страница 7: ...g Attach each side curtain to the window sash using screws ITEM G FIG 13 ITEMG I 1 LI L _ __ t FIG 13 _J Attach the L bracket ITEM J with screw iTEM G FIG 14 7 ITEM J FIG 14 DRAINAGE Be sure to insert the drain pipe into base pan before installation The air conditioner must be installed with a slight tilt to the outside for proper water drainage The air conditioner will drain the excess condensed ...
Страница 8: ...l raise the L bracket as shown in FIG 22 1 1 2 rain WOOD STRIP MOUNTED 38ram ON TOP OF INNER SILL I _ 314 CLEA NCE _ STORM WINDOW _ FIG 22 REMOVAL FROM WINDOW Turn off and unplugthe air conditioner Removethe front grille See HOW TO REMOVE THE FRONT GRILLE Refer to page 12 Unscrewthe sidescrewsthat youinstalledin Step 15 Slide the air conditionerout of the cabinet BE CAREFUL NOT TO DROP IT Holdonto...
Страница 9: ...g sound coming from your air conditioner after it is off These are normal coolant noises i ompressor The modern high efficiency compressor may have a high pitched hum or pulsating noise that cycles on and off Unit Vibration The unit may vibrate and make noise because of poor wall or window construction You may hear droplets of water hitting the condenser causing a pinging or clicking sound Fan You...
Страница 10: ...t the highest COOL level 5 Adjust the louver for comfortable air flow 6 Once the room has cooled adjust the TEMP and MODE control to the setting you t_nd most comfortable NOTE If the air conditioner is turned off wait 3 minutes before restarting This allows pressure inside the compressor to equalize Failure to wait 3 minutes before restarting may cause inefficient operation If you move the TEMP Co...
Страница 11: ...um fan speed operation Cooling with the low fan speed operation HORIZONTAL AIR DIRECTION CONTROL The horizontal air direction is adjusted by moving the vertical louvers right and left with your fingertips FIG 26 VENT CONTROL The Vent Control allows the air conditioner to either recirculate inside air CLOSE or exhaust air to the outside OPEN FIG 27 The CLOSE position is used when maximum cooling is...
Страница 12: ...e Push the grille up from the bottom and pull the top of the grille away from the case to lift the top tabs out of their slots Inlet Grille I _ Front Grige m FIG 32 AIR CONDITIONER CLEANING Clean the front grille and inlet grille by wiping with a cloth dampened Kna mild detergent solution The cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid appliance w...
Страница 13: ...Maintenance section of ownersmanual To defrost setseleolorto FANposition Todefrost thecoil setselector toa FANposition Then settheMODE control atFANposition or High_ withtheTEMPconlml toa warmer posilion THEAIRCONDmONER COOUNG BUTROOM 18TOOWARM NOICEFORMING ONCOOUNG COILBEHINDINLET GRILLE Check if Dirtyairfilter air restricted TEMPControleattonwarm Frontof unitis blockedby drapes blinds fumiture e...
Страница 14: ...ditioner To order Parts call Toll Free Model No 580 71121100 1 800 4 MY HOME 1 800 469 4663 CAUTION Use the Kenmore part number on all orders not the illustration number CABINET FRONT GRILLE ASS Y 2 A 3 A 11 00 14 ...
Страница 15: ...DESCRIPTION 1 A 3530AR1534A FRONT GRILLE 2 A 3530AR1535A INLET GRILLE 3 A 5231AR1152A AIR FILTER ASS Y 4 A 5990AR2974A VANE 5 A 4941AR7134B KNOB ASS Y 6 A 3091AR2286N CABINET ASS Y 7 A 4974AR3262E UPPER GUIDE 8 A 3850A20046L LABEL ENERGY 9 A 4758AR7211A LOUVER 3828A20049N MANUAL OWNER S Functional Parts Non illustrated Parts 15 11 00 ...
Страница 16: ...580 71121100 CAUTION Use the Kenmore part number on all orders no_tt the illustration number CONTROL BOX ASS Y 5 B 6 B 1 B 10 B 11 00 16 ...
Страница 17: ...ON 1 B 4994AR1494D 2 B 0CZZA20001M 3 B 4H00442F 4 B 2H00677S 5 B 2H01109L 6 B 2H00598E 7 B 4H01762A 8 B 3550AR7032A 9 B 6631AR3843B 10 B 6631AR2687A CONTROLBOX CAPACITOR CAPACITOR CLAMP POWER CORD ASS Y THERMOSTAT ROTARY SWITCH HOLDER PC COVER CONTROLBOX CONNECTOR ASS Y CONNECTOR ASS Y Functional Parts Non illustrated Parts 17 11 00 ...
Страница 18: ...580 71121100 CAUTION Use the Kenmore part number on all orders no__t the illustration number AIR HANDLING CYCLE PARTS 13 C 10 C 12 C 14 C 2 C i 20 C 11 C 18 C 10 C 19 C 15 C Y _c 16 C 1 C 11 00 18 ...
Страница 19: ...60A20005A MOTOR MOUNT 6 C 4681A20027H MOTOR ASS Y 7 C 3072A20001A SCROLL 8 C 5900A20002B FAN TURBO 9 C 5900AR 1173A FAN 10 C 3H02932B CLAMP SPRING 11 C 4998AR1496A SHROUD 12 C 4800A10001A BRACE 13 C 5421AR2910E EVAPORATOR ASS Y 14 C 5403AR2921A CONDENSER ASS Y 15 C 4H02023A DRAIN RUBBER 16 C 4H01029D WASHER RUBBER 17 C 3H02773A DRAIN PIPE 18 C 4790A20022A BARRIER 19 C 5040AR4254A RUBBER 20 C 3530A...
Страница 20: ...580 71121100 CAUTION Use the Kenmore part number on all orders no __tt the illustration number COMPRESSOR PARTS 8 D 7_ _ o _ I 5 D _ 2 D 4 D _ 3_ 1_o _t 9 D 12 D 14 D 13 D 11 11 00 20 ...
Страница 21: ...D 6750U L029A 7 D 3550U L004A 8 D 4H01058A 9 D 4H00947A 10 D 5211AR2930A 11 D 5211A20228A 12 D 5211A20131D 13 D 5211AR7059B 14 D 5211A20020S ISOLATOR COMP COMPRESSOR BRACKET WASHER HEXAGON NUTS GASKET OVERLOAD PROTECTOR TERMINAL COVER GASKET NUT TERMINAL COVER NUT TUBE ASS Y DISCHARGE TUBE ASS Y SUCTION TUBE ASS Y EVAPORATOR TUBE ASS Y CONNECTOR TUBE ASS Y CAPILLARY Functional Parts Non illustrate...
Страница 22: ...580 71121100 CAUTION Use the Kenmore part number on all orders not the illustration number INSTALLATION KIT ASS Y o 11 00 ...
Страница 23: ...tion number INSTALLATION KIT ASS Y POS NO PART NO DESCRIPTION 1 E 4959h R3402C SIDE CURTAIN ASS Y 2 E 4959AR3402D SIDE CURTAIN ASS Y 3 E 4810AR3240A SILL SUPPORT BRACKET 4 E 1BHD1004006 BOLT 5 E 1NHC1000006 NUT 6 E 4H01785B L BRACKET Functional Parts Non illustrated Parts 23 11 00 ...