background image

Содержание 41784092500

Страница 1: ... dryer is installed correcdy and safely Leave these instructions near the Dryer after installation for future reference NOTE The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code ANSI NEPA 70 NOTE The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the National Fuel Gas...

Страница 2: ...ated at 240 volt AC minimum 30 amp with 3 open end spade lug connectors with upturned ends or closed loop connectors OR a 4 onductor power supply cord NEMA 14 30 type SRDT or ST as required rated at 240 volt AC minimum 30 amp with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers If being installed in a manufactured mobile home the ...

Страница 3: ...re hazard as well as increase drying times Do not screen the exhaust ends of the vent system nor use any screws or rivets to assemble the exhaust system Lint can become caught in the screen on the screws or rivets clogging the duct work and creating a fire hazard as well as increasing drying times Use an approved vent hood to terminate tile duct outdoors and seal all joints with duct tape All male...

Страница 4: ...1 27 cm pipe 3 If odes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or plastic coated brass 4 The gas supply line MUST have an individual shutoff valve 5 A I 8 inch 0 32 cm N P T plugged tapping accessible for test gauge connection MUST be installed immediately upstream of the gas supply connection to the dry...

Страница 5: ...60 square inches 387 square centimeters 3 inches 7 6 cm from bottom and top of door NOTE Under counter and stack models 0 inches 0 cm for sides rear and top This dryer MUST be exhausted outdoors 5 The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation CLOSET DOOR II 0 _ _ Ocm II 0 0 cm 38 1 cm II I _ll_ 2 54 cm _ 0 0 cm 0 _ cm ...

Страница 6: ...r knobs 70 49cm 28 5 to clear door handle 72 39cm Doo i if I 1P _ _ _ _ Ft _2 375 I O3cm 13 5 To rear base exhaus 27 0 I C 58cm Electrical supply on rear of unit 34 29cm 5tacked Dryer tnstMlation Dimensions I 28 25 to front of cabinet 71 75cm 28 75 to clear knobs 73 03cm 29 5 to clear door handle 49 to clear open door 124 45cm T 72 00 11 12cm 182 88cm 4 375 Side exhausts 41 00 104 14cm Center line...

Страница 7: ...NSI Z 21 5 1 or ANSVUL2158 CAN CSA C222 latest editions for HOME USE only 1 Using the four shipping carton corner posts two on each side carefully Jay the dryer on its left side and remove the foam shipping base To prevent damage do not use the control panel as a means to pick up or move the dryer 2 Return the dryer to an upright position FOAM SHIPPING Correct REVERSING DOOR SWING Your dryer is de...

Страница 8: ...remove the plugs Be careful to avoid scratching the paint 5 Remove the two handle screws and remove the handle by pulling straight out from door 6 Install the plugs from Step 3 into the holes left by removing the handle screws in Step 4 7 Lay the door on a flat surface and support the edges of the door to keep it from turning Apply moderate downward pressure on the lens with both hands and rotate ...

Страница 9: ... a copper wired power cord with a copper wired receptacle NOTE Dryers operating on 208 volt power supply will have longer drying times than operating on 240 volt power supply 2 If your dryer is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired receptacle that is properly installed and grounded in...

Страница 10: ...ain relief nut securely so that the strain relief does not turn 9 Reinstall the terminal block cover J 1 10 ELECTRICAL CONNECTIONS FOR 4 WIRE SYSTEM ELECTRIC Dryer Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner Install a U L approved strain relief in the entry hole of the mounting bracket Finger tighte...

Страница 11: ...mable vapors Also see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 5 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off...

Отзывы: