68 / 79
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury,
disconnect unit from power before servicing unless tests require power.
11-15. Condenser Fan Motor in the Machine Room
Step
Description
Step
Description
1
5
2
6
3
7
4
□
Remark :
11. Disassemble/Assemble Procedures
※ Follow the reverse order when assembling.
Disconnect the connector
of C Fan Motor.
Loosen 2 screws.
Push the fixing hook
in the left direction
to separate the C
Fan Motor
Assembly.
Supporting the back side of
fan with 2 fingers, pull out and
remove the fixing spring with
a long nose plier. If necessary,
scratch the lock paint(green
one).
※
The diameter and shape of
this C Fan is different from the
F and C Fan.
Break the shaft(plastic) of fan blade. Do not use the
old fan again. Be careful not to damage the shaft of
motor if the motor is used again. If necessary,
scratch the lock paint(green one).
Loosen 2 screws.
Remember how to
arrange the wires.
Remove the C fan motor.