64 / 79
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury,
disconnect unit from power before servicing unless tests require power.
11-11. Refrigerator Fan and Fan Motor in freezer
Step
Description
Step
Description
1
5
2
6
3
7
4
□
Remark :
11. Disassemble/Assemble Procedures
※ Follow the reverse order when assembling.
Loosen 3 special
screws(stay bolts) and
disconnect the
connector.
Separate the R Fan
Motor assembly.
NG
Show the left picture. If you
strongly pull out the fan blade
and remove, the fan and shaft
of the motor will be damage
and have a bad performance.
Remember how to
arrange the wires.
Remove wires from a
hooks. And loosen a
screw to remove the
cable clamp.
Loosen the opposite
screw and remove
the rubber vibration
isolator.
If necessary, remove the
rubber vibration isolator in the
front of the Fixture R Motor.
Supporting the back side of fan
with a finger, pull out and
remove the fixing spring with a
long nose plier. If necessary,
scratch the lock paint(green
one).
Break the shaft(plastic) of fan blade. Do not use the
old fan again. Be careful not to damage the shaft of
motor if the motor is used again.
Remove the fan and motor.
※
The diameter and shape of
this R Fan is different from the
F and C Fan.