11-10. Freezer Sensor, F Fan and Fan Motor
Step
Description
Step
Description
1
5
2
6
3
7
4
8
□
Remark :
11. Disassemble/Assemble Procedures
※ Follow the reverse order when assembling.
Remove the tape to separate wires of F-sensor and
F Fan motor.
Loosen 7 screws marked by circle and rectangle to
remove F-sensor.
Separate the wires from
hook.
Make a gap slightly
and remove the D-
sensor from the
hook.
NG
GOOD
Loosen 4 screws
marked by rectangle.
And remove F Fan
motor assembly from
the Louver.
Remember how to
arrange the wires.
Remove wires from 3
hooks and loosen 2
screws to remove the
motor.
Break the shaft(plastic) of fan blade. Do not use the
old fan again. Be careful not to damage the shaft of
motor if the motor is used again. Remove the fan
and motor.
Show the left picture. If you strongly
pull out the fan blade and remove, the
fan and shaft of the motor will be
damage and have a bad performance.
NG
Supporting the back side of fan
with a finger, pull out and
remove the fixing spring with a
long nose plier. If necessary,
scratch the lock paint(green
one).
※
The diameter and shape of
this F Fan is different from the
R and C Fan.