background image

5

Side View

1

3

/

4

"

(44 mm)

36"

(914 mm)

20

3

/

4

"

(527 mm)

Back View

1

3

/

4

"

(44 mm)

3

1

/

4

"

(83 mm)

3

1

/

2

"

(89 mm)

11

7

/

8

"

(303 mm)

29

1

/

4

"

(743 mm)

Minimum spacing for recessed area  

and closet installation

The following dimensions shown are for the minimum spacing 

allowed when the dryer is to be operated with, or without, the 

Stack Stand Kit. To purchase a Stack Stand Kit, see the back cover. 

 

Additional spacing should be considered for ease of installation 

and servicing.

 

Additional clearances might be required for wall, door, and 

floor moldings.

 

For closet installation with a door, minimum ventilation 

openings in the top and bottom of the door are required. 

Louvered doors with equivalent ventilation openings  

are acceptable.

 

Companion appliance spacing should also be considered.

Recessed or closet installation – Dryer only

18"

(457 mm)

5

1

/

2

"*

(140 mm)

14" max.

(356 mm)

3"

(76 mm)

3"

(76 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

1"

(25 mm)

1"

(25 mm)

Recessed or closet installation – Stacked

3"

(76  mm)

3"

(76 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

1"

(25 mm)

1"

(25 mm)

12"

(305 mm)

12"

(305 mm)

5

1

/

2

"*

(140 mm)

3"

(76 mm)

* Most installations require a minimum 5½" (140 mm) clearance  

behind the dryer for the exhaust vent with elbows. See “Venting  

Requirements.”

Mobile Home – Additional Location Requirements

This dryer is suitable for mobile home installations. The installation 

must conform to the Manufactured Home Construction and Safety 

Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard 

for Mobile Home Construction and Safety, Title 245, HUD Part 

280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

 

Metal exhaust system hardware, which is available for 

purchase from your dealer.

 

Special provisions must be made in mobile homes to introduce 

outside air into the dryer. The opening (such as a nearby 

window) should be at least twice as large as the dryer  

exhaust opening.

Closet door with vents

Recessed area

Closet door with vents

Recessed area

DRYER

WASHER

Содержание 110.84422610

Страница 1: ...ble des matières 34 Kenmore 120 Volt Electric Compact Dryer Secadora compacta électrica de 120 voltios Sécheuse électrique compacte 120 volts Model Modelo Modèle 110 84422610 P N W10832415B Sears Brands Management Corporation Hoffman Estates IL 60179 U S A www kenmore com Sears Canada Inc Toronto Ontario Canada M5B 2C3 www sears ca ...

Страница 2: ...2 DRYER SAFETY DRYER SAFETY 2 INSTALLATION INSTRUCTIONS 3 USING YOUR DRYER 10 DRYER CARE 12 TROUBLESHOOTING 13 PROTECTION AGREEMENTS 16 WARRANTY 16 ASSISTANCE OR SERVICE Back Cover TABLE OF CONTENTS ...

Страница 3: ...all shipping material To avoid damaging the floor use the top of the carton to slide the dryer into place Stand the dryer up Remove the tape from the dryer door Open the dryer door and remove the parts bag from the dryer drum Close the door INSTALLATION INSTRUCTIONS ...

Страница 4: ...stallation See Venting Requirements A 120 volt 60 Hz AC only 15 or 20 amp circuit A grounded electrical outlet located within 2 ft 610 mm of either side of the dryer See Electrical Requirements A sturdy floor to support the dryer weight dryer and load of 115 lbs 52 kg The combined weight of a companion appliance should also be considered A level floor with a maximum slope of 1 25 mm under entire d...

Страница 5: ...24 in 2 155 cm2 48 in 2 310 cm2 1 25 mm 1 25 mm Recessed or closet installation Stacked 3 76 mm 3 76 mm 24 in 2 155 cm2 48 in 2 310 cm2 1 25 mm 1 25 mm 12 305 mm 12 305 mm 51 2 140 mm 3 76 mm Most installations require a minimum 5 140 mm clearance behind the dryer for the exhaust vent with elbows See Venting Requirements Mobile Home Additional Location Requirements This dryer is suitable for mobil...

Страница 6: ... the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician Venting Venting Requirements WARNING To reduce the risk of fire this dryer MUST BE EXHAUSTED OUTDOORS IMPORTANT Observe all governing codes and ordinances Dryer exhaust must not be connected into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building Only rigid or flexi...

Страница 7: ...e possible A B C A Exhaust hood B Flexible metal or rigid metal vent C Elbow Alternate installations for close clearances Venting systems come in many varieties Select the type best for your installation Two close clearance installations are shown Refer to the manufacturer s instructions A B A Over the top installation also available with one offset elbow B Periscope installation NOTE The followin...

Страница 8: ...s or elbows Type of vent Box or louvered hoods Angled hoods 0 Rigid metal 36 ft 11 m 26 ft 7 9 m 1 Rigid metal 26 ft 7 9 m 16 ft 4 9 m 2 Rigid metal 16 ft 4 9 m 6 ft 1 8 m Install Vent System 1 Before installing the vent system be sure to remove the wire exhaust guard that is located at the exhaust outlet 2 Install exhaust hood 12 min 305 mm 12 min 305 mm Install exhaust hood and use caulking comp...

Страница 9: ...e all packaging materials 4 Check dryer s final location Be sure vent is not crushed or kinked 5 Check that dryer is on a level surface 6 Plug into a grounded 3 prong outlet 7 Remove film on the console and any tape remaining on dryer 8 Remove tape from lint screen located on inside back wall of dryer 9 Read Using Your Dryer 10 Wipe dryer drum interior thoroughly with a damp cloth to remove any du...

Страница 10: ...ot pack the dryer Allow space for clothes to tumble freely 3 Turn the Cycle Control knob to the recommended cycle for the type of load being dried See Drying Cycle and Temperature Tips 4 Press PUSH TO START Stopping and Restarting You can stop your dryer anytime during a cycle To stop your dryer Open dryer door or turn Cycle Control knob to OFF NOTE The Cycle Control knob should point to an Off ar...

Страница 11: ...ng closer to Less the next time you dry a similar load If the load is not as dry as you like complete drying using the Timed Dry cycle The next time you dry a similar load select a setting closer to More How Auto Moisture Sensing Works With Auto Moisture Sensing the dryness of the load is determined by two metal strips sensors located on the inside of the dryer The metal strips help detect the amo...

Страница 12: ...cover and body with hot water 3 Wet a nylon brush with hot water and liquid detergent Scrub lint screen cover and body with the brush to remove residue buildup 4 Rinse with hot water 5 Thoroughly dry lint screen cover and body with a clean towel Replace in dryer Cleaning the Dryer Interior To clean dryer drum 1 Make a paste with powdered laundry detergent and very warm water 2 Apply paste to a sof...

Страница 13: ...y and continuously in the Timed and Air Dry cycles Dryer set to Auto Dry The timer moves only when the clothing is mostly dry See How Auto Moisture Sensing Works in Using Your Dryer Unusual Noise Thumping noise Dryer hasn t been used in a while This is normal The thumping sound should diminish after a few minutes of use Rattling or vibrating noise A small object is caught between the edges of drye...

Страница 14: ...ng the moisture sensors during Automatic cycles Check the levelness of the dryer All 4 casters should be in firm contact with the floor The Air Dry temperature setting has been selected Select the correct temperature for the types of garments being dried See Cycles The load is too large and heavy to dry quickly Separate the load to tumble freely Fabric softener sheets are blocking the lint screen ...

Страница 15: ... dyes in clothes Drum stains are caused by unstable dyes in clothing usually blue jeans These will not transfer to other clothing Dry unstable dye items like blue jeans inside out to avoid transfer of dye to drum Loads are wrinkled The load was not removed from dryer at the end of the cycle Refer to garment care label instructions Dry clean only garments are not recommended The dryer was tightly p...

Страница 16: ...age www kenmore com warranty This warranty applies for only 90 DAYS from the sale date in the United States and is void in Canada if this appliance is ever used for other than private household purposes This warranty covers ONLY defects in material and workmanship and will NOT pay for 1 Expendable items that can wear out from normal use including but not limited to filters belts bags or screw in b...

Страница 17: ...ademark of KCD IP LLC in the United States or Sears Brands LLC in other countries Marca Registrada Marca de Fábrica de KCD IP LLC en Estados Unidos o Sears Brans LLC en otros países MC Marque de commerce MD Marque déposée de Sears Brands LLC ...