1.2 X5 Power Source 400 and 500
This section describes the structure of X5 Power Source 400 and X5 Power Source 500.
Front:
1.
Indicator panel *
2.
Transportation handle (not intended for mechanical lifting)
3.
Front locking interface (locking on top of the cooling unit or on the cart)
* Indicator panel
1.
VRD (Voltage Reduction Device) indicator
>> The LED is green when VRD is switched on and the no-load voltage is under 35 V.
>> The LED blinks red when VRD is switched on and the no-load voltage is above 35 V.
>> The LED is off when VRD is switched off or during welding.
>> The LED blinks green when the MMA or Gouging power save mode is on (the power save mode is automatically
applied after 15 minutes of idling).
VRD is in use with MMA and Gouging modes only.
2.
High temperature indicator (overheating)
>> The LED is yellow when the unit is overheating.
If the power source overheats, a thermal cutoff switches the unit off and does not allow it to be used until it has
cooled down.
3.
Power on/off indicator
>> The LED is green when the unit is on.
4.
Coolant temperature warning
>> The LED is yellow when the cooler is overheating.
If the coolant liquid overheats, a thermal cutoff switches the welding system off and does not allow it to be used
until the coolant liquid has cooled down.