4.5 Error codes
In error situations, the control panel displays the number and title of the error. The X5 Wire Feeder 300 Auto control
panel also shows the possible cause and a proposed action to fix the issue.
Error
Code
Title
Possible cause
Proposed action
1
Power source
not calibrated
Power source calibration has been lost.
Restart the power source. If problem persists, contact
Kemppi service.
2
Too low mains
voltage
Voltage in mains network is too low.
Restart the power source. If problem persists, contact
Kemppi service.
3
Too high
mains voltage
Voltage in mains network is too high.
Restart the power source. If problem persists, contact
Kemppi service.
4
Power source
is overheated
Too long welding session with high power.
Do not shut down, let the fans cool the machine. If fans are
not running, contact Kemppi service
5
Internal 24V
voltage is too
low
Power source contains an inoperative 24V
power supply unit .
Restart the power source. If problem persists, contact
Kemppi service.
7
Wire feeder
not found
Wire feeder is not connected to power source
or connection is faulty.
Check the control cable and its connectors.
9
Measurement
cable failure
Voltage sensing cable is not connected to the
work piece or measurement cable connection is
faulty.
Connect voltage sensing cable to the work piece and
check the measurement cable and its connectors.
11
FET unit failure
Power source contains an inoperative FET unit.
Restart the power source. If problem persists, contact
Kemppi service.
12
Welding cable
failure
Plus and minus cables are connected together.
Check the connections of welding cable and earth return
cable.
13
IGBT over-
current
Inoperative mains transformer in power source.
Restart the power source. If problem persists, contact
Kemppi service.
14
IGBT over-
heated
Too long welding session with high power or
high ambient temperature.
Do not shut down, let the fans cool the machine. If fans are
not running, contact Kemppi service.
17
Phase is miss-
ing from
mains supply
One or more phases are missing from the mains
supply.
Check the mains cable and its connectors. Check the
voltage of mains supply.
20
Power source
cooling failure
Cooling capacity is reduced in the power
source.
Clean the filters and clear any dirt from the cooling channel.
Check that the cooling fans are running. If not, contact
Kemppi service.
24
Cooling liquid
overheated
Too long welding session with high power or
high ambient temperature.
Do not turn off the cooler. Let the liquid circulate until the
fans cool it down. If fans are not running, contact Kemppi
service.
26
Cooling liquid
not circulating
No cooling liquid or circulation is blocked.
Check the liquid level in the cooler. Check hoses and con-
nectors for blockage.
27
Cooler not
found
Cooling is turned on in the settings menu, but
cooler is not connected to power source or
cabling is faulty.
Check the cooler connections. Ensure that the cooling is
turned off in the settings menu, if the cooler is not in use.
33
Welding cable
calibration fail-
ure
Welding cable calibration failed.
Check the welding system cables and their connections.
© Kemppi
95
1920960 / 2039
Содержание X5 FastMig Manual 400
Страница 1: ...X5 FastMig Operating manual EN X5 FastMig Kemppi 2 1920960 2039...
Страница 29: ...X5 FastMig Operating manual EN Kemppi 30 1920960 2039...
Страница 36: ...X5 FastMig Operating manual EN 1 2 Kemppi 37 1920960 2039...
Страница 108: ...X5 FastMig K ytt ohje FI X5 FastMig Kemppi 109 1920960 2039...
Страница 136: ...X5 FastMig K ytt ohje FI Kemppi 137 1920960 2039...
Страница 143: ...X5 FastMig K ytt ohje FI 1 2 Kemppi 144 1920960 2039...