X5 FastMig
Operating manual - EN
2.1 Installing power source mains plug
Only an authorized electrician is allowed to install the mains cable and plug.
Do not connect the machine to the mains before the installation is complete.
Install the 3-phase plug according to the X5 FastMig power source and site requirements. Refer also to "Technical
data" on page 100 for power source specific technical information.
The mains cable includes the following wires:
1.
Brown: L1
2.
Black: L2
3.
Grey: L3
4.
Yellow-green: Protective earth
Cable type and fuse rating requirements:
Unit amperage
High voltage version (380-460V)
Cable type
Fuse rating
400 A
4 mm
2
25 A
500 A
6 mm
2
32 A
© Kemppi
21
1920960 / 2039
Содержание X5 FastMig Manual 400