MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Operating manual - EN
To adjust parameters:
1.
Go to the
Start & stop
sequence view.
2.
Turn the control knob (1) to browse through the parameters.
3.
Select a parameter for adjusting by pressing the control knob button (1).
4.
Adjust the parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob (1).
Adjustable parameters in all welding modes:
Parameter
Value
Note
Trigger logic
2T / 4T / 4T LOG / 4T LOG + Minilog (Default =
2T)
Welding mode
Continuous / Spot / MicroTack
Welding current
Default = 50 A
Ignition mode
Lift TIG / High frequency (HF) ignition
Adjustable parameters in continuous welding:
Parameter
Value
Note
Pre gas
0.0 s ... 10.0 s, Auto, 0.1 s step (Default =
Auto)
Search arc
OFF / 5 % ... 90 %, step 1 % (Default = OFF)
Upslope
OFF / 0.1 s ... 5.0 s, 0.1 s step (Default = 0.0 s)
Hot start level
-80 % ... 100 %, 1 % step (Default = OFF, 0
%)
Hot start time
0.1 s ... 5.0 s, 0.1 s step (Default = 1.2 s)
This is not available with 4T trigger logic.
Minilog level
-99 % ... 125 %, 1 % step (Default = OFF, 0
%)
© Kemppi
42
1920900 / 2052