MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Operating manual - EN
MIX TIG AC ratio
10 % ... 90 %, step 1 % (Default = 50 %)
MIX TIG cycle time
0.1 s ... 1.0 s, step 0.1 s (Default = 0.6 s)
MIX TIG DC level
50 % ... 150 %, step 1 % (Default = 100 %)
MicroTack spot time
1 ms ... 200 ms, step 1 ms (Default = 10 ms)
MicroTack pause time
50 ms ... 500 ms, step 1 ms (Default = 50 ms)
MicroTack spot count
1 ... 5, Endless (Default = 1)
Arc force
-10 ... +10 , step 1 (Default = 0)
Hot start
-10 ... +10 , step 1 (Default = 0)
VRD
OFF / ON (Default = OFF)
In AU VRD (Voltage Reduction Device) version:
Default ON, OFF disabled.
MMA Antifreeze
OFF / ON (Default = ON)
HF spark force
50 % ... 110 %, Step 1 % (Default 100 %)
TIG antifreeze
OFF / ON (Default = OFF)
Remote mode
OFF / Remote / Torch (Default = OFF)
Remote control min
Min = “Current limit min”, Max = “Current limit
max”
Remote control max
Min = “Current limit min”, Max = “Current limit
max”
Wireless remote
Cancel / Start (Start pairing)
Water cooler
OFF / Auto / ON (Default: Auto)
Weld data time
OFF / 1 s ... 10 s, step 1 s (Default = 5 s)
Display off
5 min ... 120 min, step 1 min (Default = 5 min)
Date
Date setting (DD/MM/YYYY)
Set the day by pressing and turning the control knob.
Once the day is set, press the control knob button to
set the month etc.
Time
Time setting (HH:MM)
Set the hour by pressing and turning the control
knob (use 24 h format). Once the hour is set, press
the control knob button to set the minutes.
Language
Select language from the list
Time counter
Total arc time and power on time
Time counter (since
date)
Total arc time and power on time since last
reset
Reset counter
Time counter reset
4T trigger logic
4T MLOG / 4T LOG / 4T LOG+ (Default = 4T
MLOG)
Advanced settings (hidden in standard view):
Parameter
Value
Note
Current limit min
TIG: 2 A / MMA: 8 A, step 1 A
*
Current limit max
TIG: power source's nominal value / MMA:
power source's max. MMA current, step 1 A
*
© Kemppi