22
A7 MIG Welder
© Kemppi Oy 2017
1735
OPERA
TING M
ANU
AL
4.2.4 User settings
User settings menu (Main menu 2/8) (login required)*
Menu item
Value range
Factory value
Description
1/5
Change PIN
code
Change your PIN code.
New PIN code
0000 - 9999
0000
Specify a new PIN code.
2/5
User mode
ON, OFF
OFF
Set the user identification mode
on and off.
3/5
Set the user
rights
Change the role for a user.
Select user
USER1 - USER10
Select the user whose role you
want to change. Note! You cannot
change your own role.
Level
Welder,
Supervisor,
Administrator
Select the role for the user.
4/5
User activation
Create and delete users.
User activation
USER1 - USER10
Select the user account that you
want to create /delete.
User
Enabled,
Disabled
Create an account by setting
the user Enabled, or delete the
account by selecting Disabled.
5/5
Reset user PIN
code
Reset the PIN code of a user.
Select user
USER1 - USER10
Select the user whose pin code
to reset. The reset value is 0000.
Confirm the reset by pressing OK
soft button.
*
See section
4.4 User identification
for more information.
4.2.5 Welding system settings
System config menu (Main menu 4/8)
Menu item
Value range
Factory
value
Description
1/20
Water cooling
OFF, ON, AUTO
AUTO
Set the water cooler on and
off, or let the system control
the cooler (AUTO). In auto
mode the water pump starts
when welding starts and
stops after a delay when
welding stops.
2/20
Cable length
10 - 100 m
10 m
Set the welding circuit length
for optimal arc control.
3/20
FineCalib
0 V - 10 V /
100 A
10 V / 100 A Set the compensation for
cable resistance variation.
4/20
System clock
View and modify the system
time and date.
5/20
Device information
Review the following device
information for each device
in the system:
DevSW: Unit software
version.
SysSW: System base software
version.
BootSW: Boot software
version.
SW Item: Software item
number.
Serial: Device serial number.
Prog: Programmer name.
Date: Programming date.
6/20
Restore settings
ROBOT All settings
All memory channels (0-199)
are restored from backup.
Setup settings remain as they
are.
Restore to factory
All memory channels and
their backups are removed.
All settings are set to default
factory values.
Содержание Kemppi A7 MIG Welder 350