SERVICE MANUAL
FASTMIG X
10 (37)
Kemppi OY
5. SECONDARY CUT OFF CARD Z004
•
Secondary cut-off card Z004 is used to make special welding characteristics. There is a need of a very quick current
cut-off in a certain stage in PipeRoot welding process
•
Mosfets V6-V45 are controlled to non-conductive state while the certain very short time period
•
In order to control those mosfets they need isolated voltage from secondary shunt-, because mosfets sources are
connected to main choke+. The isolated v15Vdc in C7 is generated from +24Vdc by using forward converter
with V1 and T1. Control gate signal is generated in the processor card A002 isolated from the mosfet gates through an
optical driver H1
•
A resistor R004 is used to reduce voltage spikes while those PipeRoot periods
•
The whole secondary current goes through secondary profile between rectifier card Z003 and cut-off card Z004
5.1. Connectors
Connector
Description
X1:1
Optical coupler anode
X1:2
Optical coupler cathode
X1:3
Not in use
X1:4
+24Vdc
X1:5
FET FAILURE signal
X1:6
GND
X5-X8
Secondary choke
Содержание FastMig X 450
Страница 1: ...20 6 2013 Kemppi Oy SERVICE MANUAL FASTMIG X FASTMIG X 450 MXP37 PIPE MXP 38...
Страница 2: ...SERVICE MANUAL KEMPACT RA Kemppi Oy...
Страница 37: ......