39
Chapter 5 Maintenance
There are no user-serviceable parts inside the controllers. Do not attempt to open the
controller
as this will void your warranty. However, periodic, exterior cleaning of the controller
should be carried out.
The controller is a high powered device. When working with any battery powered vehicle,
proper safety precautions should be taken that include, but are not limited to, proper training,
wearing eye protection, avoidance of loose clothing, hair and jewelry. Always use insulated
tools.
5.1 Cleaning
Although the controller requires virtually no maintenance after properly installation, the following
minor maintenance is recommended in certain applications.
•
Remove power by disconnecting the battery, starting with battery positive.
•
Discharge the capacitors in the controller by connecting a load (such as a contactor coil,
resistor or a horn) across the controller’s B+ and B- terminals.
•
Remove any dirt or corrosion from the bus bar area. The controller should be wiped with a
moist rag. Make sure that the controller is dry before reconnecting the battery.
•
Make sure the connections to the bus bars, if fitted are tight. To avoid physically stressing
the bus bars use two, well-insulated wrenches.
5.2 Configuration
You can configure the controller with a host computer through either an RS232 or USB port.
•
Disconnect motor wiring from controller for configuring existing parameters in the user
program or Android APP. If this operation is too much extra job for you, please make sure
the motor must be stopped before programming.
•
The controller may display fault code, but it doesn't affect programming or configuration.
But it will affect the Identification angle operation. Please try to eliminate the error codes
before Identification angle operation.
•
Use a straight through RS232 cable or USB converter provided by Kelly to connect to a
host computer. Provide >+18V to PWR
(
for a 24V controller, provide >+8V
)
. Wire power
supply return(supply negative) to any RTN pin.
•
KLS controller requires a 4pin connector to Kelly RS232 Converter to support the
communication. And customers may need a Z-TEK USB cable for Tablet with Android OS.
Customers may download PC software or Android APP to program the controller
before running the motor. You may do Identification angle for brushless motor with
hall sensors after running the software or Android APP. Every item in the
configuration program can show the explanation automatically when you click it.
Содержание KLS8425RM
Страница 8: ...8 Figure 1 KLS7225RM KLS7230RM KLS8428RM mounting holes dimensions dimensions in millimeters...
Страница 9: ...9 Figure 1 KLS8425RM mounting holes dimensions dimensions in millimeters...
Страница 10: ...10 Figure 2 KLS7235RM KLS7240RM KLS8430RM KLS8445RM mounting holes dimensions dimensions in millimeters...
Страница 11: ...11 Figure 3 KLS7245RM mounting holes dimensions dimensions in millimeters...
Страница 12: ...12 Figure 3 KLS8428RM mounting holes dimensions dimensions in millimeters...
Страница 13: ...13 Figure 4 KLS8460RM mounting holes dimensions dimensions in millimeters...
Страница 14: ...14 Figure 4 KLS7250RM KLS7260RM mounting holes dimensions dimensions in millimeters...
Страница 17: ...17 Figure 6 KLS RMO model with Sealed Aluminium Housing mounting holes dimensions dimensions in millimeters...
Страница 19: ...19 3 2 Connections 3 2 1 Pin definition of KLS N Controller Figure 10 waterproof connector...
Страница 20: ...20 Figure 11 Compact connectors...
Страница 35: ...35 2 Please connect the controller to user program by using an USB to RS232 cable and SM 4A DB9 RS232 Converter...