2.3 Specifications 

Frequency of Operation: 10KHz or 20KHz. 

Standby Battery Current: < 0.5mA. 

5V or 12V Sensor Supply Current: 40mA. 

Controller supply voltage range: PWR, 18V to 86V for controllers rated equal or lower than   

  72V.   

Supply Current, PWR, 30mA Typical. 

Configurable battery voltage range, B+.   

Standard Throttle Input: 0-5 Volts(3-wire resistive pot), 1-4 Volts(hall active throttle). 

Throttle Input: 0-5 Volts. Can use 3-wire pot to produce 0-5V signal. 

Full Power Operating Temperature Range: 0

  to 70

(MOSFET temperature). 

Operating Temperature Range: -40

to 100

  (MOSFET temperature). 

Max Battery Current :Configurable. 

 
 
 

2.4 Name Regulation 

The name regulation of Kelly BLDC motor controllers

 

 
KLS7230S 
KLS: Kelly BLDC motor controller based on sinusoidal waveform which is supposed to 
work with BLDC motor with three hall sensors. 
72: 72V batteries 
S: Mini case for the controller

 

 

Kelly KLS-S Space-saving Sinusoidal Brushless Motor Controller 

Model 

1 Minute Boost 

Current(Amp) 

Continuous 

Current(Amp) 

Nominal 

Voltage(Volt) 

Max Operating 

Voltage(Volt) 

KLS4812S 

120 

50 

36-48 

30-60 

KLS4818S 

200 

80 

36-48 

30-60 

KLS4830S 

300 

120 

36-48 

30-60 

KLS7212S 

120 

50 

48-72 

40-86 

KLS7218S 

200 

80 

48-72 

40-86 

KLS7230S 

300 

120 

48-72 

40-86 

 
 
 
 

Содержание Cheetah Series

Страница 1: ...Permanent Motor Controller User s Manual V1 13 Kelly Cheetah series KLS S Light flexible Sinusoidal Permanent Magnet Motor Controllers User s Manual Devices Supported Rev1 13 Jan 2023 KLS4812S KLS7212...

Страница 2: ...r 3 Wiring and Installation 6 3 1 Mounting the Controller 6 3 2 Connections 9 3 3 Installation Check List 14 Chapter 4 Programmable Parameters 15 4 1 Step 1 15 4 2 Step 2 20 4 3 Step 3 21 4 4 How to u...

Страница 3: ...efficiency requirements in the application of DC brushless motor It uses high power MOSFET s and SVPWM and FOC to achieve efficiencies of up to 99 in most cases A powerful microprocessor brings in co...

Страница 4: ...5 switch inputs which are activated by connection to 12V Default to throttle switch brake switch reversing switch forward switch and Boost switch 11 3 analog 0 5V inputs that default to throttle inpu...

Страница 5: ...luminum housing for maximum heat dissipation and harsh environment 15 Rugged high current terminals and rugged aviation connectors for small signal 16 Thermal protection current cut back warning and s...

Страница 6: ...Operating Temperature Range 0 to 70 MOSFET temperature Operating Temperature Range 40 to 100 MOSFET temperature Max Battery Current Configurable 2 4 Name Regulation The name regulation of Kelly BLDC m...

Страница 7: ...m water and contaminants To ensure full rated output power the controller should be fastened to a clean flat metal surface with four screws Applying silicon grease or some other thermal conductive mat...

Страница 8: ...Kelly KLS S Cheetah series Sinusoidal Permanent Motor Controller User s Manual V1 13 7 Figure 2 KLS 18S mounting holes dimensions dimensions in millimeters...

Страница 9: ...Kelly KLS S Cheetah series Sinusoidal Permanent Motor Controller User s Manual V1 13 8 Figure 3 KLS 30S mounting holes dimensions dimensions in millimeters...

Страница 10: ...ow This 12V only can be used for LED or switch signals 3 Boost and Brake analog regeneration mode used the same pin as pin2 When Boost is disabled in the user program the pin2 can be used as brake var...

Страница 11: ...1 Temp Motor temperature sensor input Raddle 5 5V 5V supply output 40mA Purple 18 Hall A Hall phase A Yellow 17 Hall B Hall phase B Dark Green 16 Hall C Hall phase C Dark Blue Notes 1 All RTN pins are...

Страница 12: ...al Permanent Motor Controller User s Manual V1 13 11 3 2 2 Wiring of KLS S Controller 3 2 2 1 Standard wiring of KLS S controller Figure 5 KLS S controller standard wiring F N R control Battery voltag...

Страница 13: ...ntroller standard wiring Three speed function control Battery voltage can be used for controller supply 3 2 2 2 Optional wiring of KLS S controller The 12V input signal of the pin supplies the second...

Страница 14: ...S controller on pin11 Figure 9 Wiring diagram for motor temperature sensor 3 2 3 Communication Port A 4pin connector to RS232 port is provided to communicate with host computer for calibration and con...

Страница 15: ...tor is still running let alone change the settings in the user program Make sure the wire is connected correctly Turn the PWR switch on The Green LED stay on steadily and Red LED turns off when the co...

Страница 16: ...in7 to batteries for Identification Angle operation Please download the instruction how to use Identification angle function from our website www kellycontroller com support php 4 1 Step 1 1 Low Volt...

Страница 17: ...e This is normal Please reset the power supply again Then everything will be fine The motor is ready to be drived by the KLS controller Range 85 or 170 nothing else 6 TPS Low Err Hall active pedal if...

Страница 18: ...tle effective ending point Suggestion Set according to the practical situation factory default is 80 5V 4 0V 14 Max output Fre Max output frequency Unit Hz Functional description It will affect the to...

Страница 19: ...actory default is Disable 21 NTL H Pedal Neutral position High Pedal Disable Only useful when Three gears switch function is enabled If enable the controller will detect the current pedal position or...

Страница 20: ...tus Forward Switch Foot Switch FWD_SW 12 REV_SW 14 Foot 15 Enable Disable OFF OFF x Neutral OFF ON x Reverse ON OFF x Forward ON ON x Neutral Disable Enable x OFF OFF Can t operate x ON OFF Can t oper...

Страница 21: ...expected after finish the Identification angle operation please just choose Change Direction item Please click Write button to activate Change Direction function The motor direction will be what you...

Страница 22: ...rottle regen mode type The regen will happen as long as the throttle is released completely Factory set is 0 2 NTL Brk NTL Braking Percent the percent of Neutral Braking in max braking Range 0 50 Only...

Страница 23: ...gram It will help the motor change the direction of motor quickly after you shift throttle from 0V to 5V or from 5V to 0V Suggestion factory default is Disable 11 Compensation Per Tried to increase th...

Страница 24: ...or Android App Tablet or Cell Phone KLS S controller is designed for BLDC motor with three hall sensors By default the speed sensor type is set at 2 from factory setting for KLS S controller 1 Please...

Страница 25: ...Tablet The third option is customers can buy our Bluetooth converter to connect the controller to Android Phone We don t have to use SM 4A to DB9 RS232 converter any more when you use Bluetooth conver...

Страница 26: ...e shipment Your motor is different from the motor from controller supplier 5 Please fill 170 in the identification angle item And please click the write button The user program will give a pop up wind...

Страница 27: ...picture of user program Please write 85 instead in identification angle by manual If there are no any error codes you can not write it back to 85 by manual Please wait longer time until the error code...

Страница 28: ...connecting a load such as a contactor coil resistor or a horn across the controller s B and B terminals Remove any dirt or corrosion from the bus bar area The controller should be wiped with a moist...

Страница 29: ...e will be regularly updated and published on the website Please Update your Configuration Software regularly You must uninstall the older version before updating Please try to use Identify function fo...

Страница 30: ...pped but will restart when temperature falls below 80 2 4 Throttle error at power up Throttle signal is higher than the preset dead zone at Power On Fault clears when throttle is released 3 1 Reserved...

Страница 31: ...or code is only valid for KLS 8080I controller Customers may read error codes in PC software or Android Tablet Contact Us Kelly Controls Inc Home Page http www KellyController com Download user manual...