Specification and Operating Instructions
Wiring Diagram
ETDT1510I_090320
Description
The timer controller acts on a relay connecting it for a
programmable time interval.
Timer features include soundwarning when the countdown expires,
count units in seconds or minutes
,
abort by the keyboard, remote
countdown input, manual control to switch ON/OFF the output,
and
maximum interval limit.
Installation
(seconds are allways indicated by
a blinking led)
countdown
programmable
Model references
NOTE: Unit must be mounted away from vibration, impacts,
water and corrosive gases.
Cut hole in panel 71 x 29 mm (2.80 x 1.14 inches)
Apply silicone (or rubber gasket) around the perimeter of the hole
to prevent leakage.
Insert unit into hole of panel.
Slide removable fitting clips onto unit from the back until secure to
panel.
Wiring diagram is displayed on the top of the unit
Maintenance, cleaning and repair
After final installation of the unit, no routine maintenance is
required.
The model reference is given by: KLT11TIM - WY.
Where each sufix can take the following values:
W Display Color
R=Red, G=Green, B=Blue
Y Supply Voltage
230=230Vac, 110=115Vac
24=24Vac/dc, 12=12Vac/dc
•
•
•
•
•
Clean the surface of the display controller with a soft and damp
cloth. Never use abrasive detergents, petrol, alcohol or solvents.
All repairs must be made by authorised personnel.
Technical Data
Storage temperature
-20ºC to 80ºC (
-
4 to 176ºF)
Operating temperature
0ºC to 70ºC (32 to 158ºF)
Time resolution
Supply voltages
115Vac±10%, 230Vac±10%, 24Vac/dc±10%, 12Vac/dc±10%
Supply powers
4VA (230V)
1 sec
Displays
3-digit
Output
SPST Relay Resistive load 16A
1HP 240Vac -- 10FLA, 60LRA 240Vac
Dimensions
Front 77 x 36 mm (3.03 x 1.42 inch)
Depth 62 mm ( 2.44 inch)
Front Protection
IP64
Back Protection
IP20
KLTIMER Timer
Controller