background image

WARNING

Please  read  this  installation  sheet  fully  and 
carefully. The F40LC Digital Pump Controller is 
a mains voltage device. Death or serious injury 
may result if this product is not correctly installed 
and used.

INTRODUCTION

The F40LC pump controller is a simple to use controller. 
It is a microprocessor based integrated pressure and flow 
device.  It  is  designed  for  controlling  the  operation  of  a 
pump and for protecting it against running dry. 

WARNING

The  F40LC  Digital  Pump  Controller  is  water 
resistant to IP67. The F40LC may present a shock 
hazard and death or serious injury may result if 
water enters its electrical housing. There are no 
user  serviceable  parts  in  this  pump  controller. 
Under  no  circumstances  should  the  main 
housing be opened. Warranty on this product is 
automatically void if the sealed body screws are 
opened.

IMPORTANT

This  installation  and  usage  information  sheet  must  be 
read with reference to the specific model controller being 
installed. The power switching capacity and the pressure 
rating of the controllers vary from model to model and it is 
very important to understand the limitations of a specific 
controller before installing it.

MODELS

SUPPLY VOLTAGE

240 = 220 TO 240VAC

CABLE

NO LETTER = 10Amp PLUG & PLAY

S = SINGLE CABLE 2M LONG WITH 4 CORES

F40-240LC-S

OPERATING ENVIRONMENT

Supply F40-240-LC

220 to 250VAC 50Hz Single Phase

Ambient Temperature Range

1ºC to 50ºC

Liquid Temperature Range 

1ºC to 60ºC

Ingress Protection Rating

IP67

Maximum Operating 
Pressure

20 Bars (300 psi)

OPERATING RANGE

Start-up Timer

Automatic 10 seconds

Run-on Timer

Automatic 10 seconds

Restart Timer 

Automatic, 4 attempts at
15 minute intervals

Pump Start Pressure Range

Adjustable 0 to 5 Bars in 16 steps

Maximum Starting Pressure

500kPa (72 psi)

Minimum Starting Pressure

33kPa (4.7 psi)

Recommended Pipe Sizes

25mm (1”) or larger
(There is no upper limit)

Maximum Switched Load

250VAC 50Hz 2.4kW (Motors up 
to 3HP)

Operating Pressure Range, 
Static or Dynamic

0 to 20 Bars (0 to 300 psi),
See note below

Burst Pressure

50 Bars (750 psi)

NOTE: The F40LC pump controller must NOT be used in hot water 
applications  (>60ºC).  The  F40LC  pump  controller  is  rated  to 
withstand water pressure to 20 Bars (300 psi) and must not be used 
in applications where the static or dynamic pressure exceeds this 
rating.

INSTALLATION

The  F40LC  is  suitable  for  use  in  all  cold  water  based 

applications such as potable water, sea water, bore water, 

chlorinated pool water, brackish water or filtered effluent. 

A suitable location should be selected for the controller in 

the delivery pipework of the pump. The controller should 

be installed in a location that is away from both vibration 

and heat, preferably out of direct exposure to the weather 

and above any flood level. A 1” BSP socket, or threaded 

pipe  tee  must  be  provided  in  the  pipework  to  fit  the 

controller. The controller should be located on the topside 

of a horizontal section of the pipework with a minimum of 

2 diameters of straight pipe either side of the controller. 

Under no circumstances mount the F40LC under a pipe 

or close to valves, tees, bends or any other obstructions 

likely to cause major turbulence in the flow. The F40LC 

can be mounted in vertical pipework if required and flow 

can pass either in an upward or downward direction.

In most installations the paddle of the F40LC will need to 

be trimmed to suit the specific pipe tee in which it is to 

be installed. The paddle of the controller needs a force 

equivalent to 20 grams dead weight acting on it from the 

flow in order to operate correctly. The force is generated 

by  water  in  motion  pushing  against  the  exposed  area 

of the paddle. The more area of paddle exposed to the 

flow the more force available to actuate the controller. Be 

INSTALLING AND USING

THE KELCO F40-240LC PUMP CONTROLLER

Отзывы: