Appendix G: Model 2400 emulation
Series 2600B System SourceMeter® Instrument Reference Manual
G-6
2600BS-901-01 Rev. B / May 2013
Model 2400 SCPI command support
The following table provides a listing of Model 2400 commands and emulation support for the Series
2600B. In the supported column: Yes indicates the command is fully supported; No indicates the
command is not supported; Partially indicates the command is supported, but with stipulations as
noted in
Model 2400 SCPI command compatibility
(on page G-15).
Subsystem
Command
Supported
:CALCulate
:CALCulate[1]:DATA:LATest?
Yes
:CALCulate
:CALCulate[1]:DATA?
Yes
:CALCulate
:CALCulate[1]:MATH[:EXPRession]
Yes
:CALCulate
:CALCulate[1]:MATH[:EXPRession]?
Yes
:CALCulate
:CALCulate[1]:MATH[:EXPRession]:CATalog?
Yes
:CALCulate
:CALCulate[1]:MATH[:EXPRession][:DEFine] <form>
Yes
:CALCulate
:CALCulate[1]:MATH[:EXPRession][:DEFine]?
Yes
:CALCulate
:CALCulate[1]:MATH[:EXPRession]:DELete:ALL
Yes
:CALCulate
:CALCulate[1]:MATH[:EXPRession]:DELete[:SELected] <SPD>
Yes
:CALCulate
:CALCulate[1]:MATH[:EXPRession]:NAME <SPD>
Yes
:CALCulate
:CALCulate[1]:MATH[:EXPRession]:NAME?
Yes
:CALCulate
:CALCulate[1]:MATH:UNITs <name>
Yes
:CALCulate
:CALCulate[1]:MATH:UNITs?
Yes
:CALCulate
:CALCulate[1]:STATe <Bool>
Yes
:CALCulate
:CALCulate[1]:STATe?
Yes
:CALCulate
:CALCulate2:CLIMits:BCONtrol IMMediate|END
Yes
:CALCulate
:CALCulate2:CLIMits:BCONtrol?
Yes
:CALCulate
:CALCulate2:CLIMits:CLEar:AUTO <Bool>
Yes
:CALCulate
:CALCulate2:CLIMits:CLEar:AUTO?
Yes
:CALCulate
:CALCulate2:CLIMits:CLEar[:IMMediate]
Yes
:CALCulate
:CALCulate2:CLIMits:FAIL:SMLocation <NRf>|NEXT
Yes
:CALCulate
:CALCulate2:CLIMits:FAIL:SMLocation?
Yes
:CALCulate
:CALCulate2:CLIMits:FAIL:SOURce2 <NRf>|<NDN>
Yes
:CALCulate
:CALCulate2:CLIMits:FAIL:SOURce2?
Yes
:CALCulate
:CALCulate2:CLIMits:MODE GRADing|SORTing
Yes
:CALCulate
:CALCulate2:CLIMits:MODE?
Yes
:CALCulate
:CALCulate2:CLIMits:PASS:SMLocation <NRf>|NEXT
Yes
:CALCulate
:CALCulate2:CLIMits:PASS:SMLocation?
Yes
:CALCulate
:CALCulate2:CLIMits:PASS:SOURce2 <NRf>|<NDN>
Yes
:CALCulate
:CALCulate2:CLIMits:PASS:SOURce2?
Yes
:CALCulate
:CALCulate2:DATA?
Yes
:CALCulate
:CALCulate2:DATA:LATest?
Yes
:CALCulate
:CALCulate2:FEED CALCulate[1]|VOLTage|CURRent|RESistance
Yes
:CALCulate
:CALCulate2:FEED?
Yes
:CALCulate
:CALCulate2:LIMit[1]:COMPliance:FAIL IN|OUT
Yes
:CALCulate
:CALCulate2:LIMit[1]:COMPliance:FAIL?
Yes
:CALCulate
:CALCulate2:LIMit[1]:COMPliance:SOURce2 <NRf>|<NDN>
Yes
:CALCulate
:CALCulate2:LIMit[1]:COMPliance:SOURce2?
Yes
:CALCulate
:CALCulate2:LIMit[1]:FAIL?
Yes
:CALCulate
:CALCulate2:LIMit[1]:STATe <Bool>
Yes
:CALCulate
:CALCulate2:LIMit[1]:STATe?
Yes
:CALCulate
:CALCulate2:LIMit[2|3|5-12]:FAIL?
Yes
:CALCulate
:CALCulate2:LIMit[2|3|5-12]:LOWer[:DATA] <NRf>
Yes
:CALCulate
:CALCulate2:LIMit[2|3|5-12]:LOWer[:DATA]? [DEFault|MINimum|MAXimum]
Yes