3-14
Setup and Installation
Table 3-2 lists interrupt levels commonly used by IBM PC and
compatible computers. Select an interrupt level that is not being used by
another resource in your system (including another DAS-8 Series board),
and set the jumper to the appropriate interrupt level. It is recommended
that you select interrupt level 3, 4, 5, or 7, if available.
Analog Output Voltage Range Adjustments
(DAS-8/AO Only)
Switches S3 and S4 are the Analog Output Range switches for D/A1 and
D/A0, respectively. Jumpers J6 and J7 set the D/A outputs into either
Voltage Output Mode or 4-20mA Current Output Mode. Settings for
these components are as shown in Figure 3-8.
Table 3-2. Interrupt Levels
Level
Use
2
Reserved (XT), interrupts 8 to 15 (AT)
3
Serial port COM2 or SDLC
4
Serial port COM1 or SDLC
5
Hard disk (XT), LPT (AT)
6
Floppy disk
7
LPT