C-8
DriverLINX Implementation Notes
External Clocking
See the External Clocking section under the Analog Input Subsystem.
Data Coding
The D/A channels use straight binary coding. The minimum value that
can be used is 0 and the maximum value is 4095. Analog output values
are determined by the Analog Output Range switches (S3 and S4). For
example, if you use the 0-5V range, the D/A output range will be as
follows:
.
If you output larger or smaller values, the high-order bits will be ignored.
So, 4096 would give an output voltage of 0V, and -1 would give an output
voltage of 5.0V.
Table C-6.
Binary Value
D/A
Output Voltage
0
0
2048
2.5V
4095
5.0V
Voltage Resolution
Vref
5V
–
=
–
4096
---------------------------------
1.22mV
=
=