A-7
Interrupt Channel
Level
2–7 Software selectable
Enable
Via INT of Control Register
Note:
On the DAS-8/AO, Interrupts latch in an internal flip-flop whose
state corresponds to the INT bit in the Status Register. A write to the
Status Register clears this flip-flop. Service routines should acknowledge
and re-enable the interrupt flip-flop.
Programmable Timer
Type
82C54 programmable interval timer
Counters
3-down counter, 16 bit
Output drive
2.2mA at 0.45V (5 LSTTL loads)
Input gate
TTL/DTL/CMOS compatible
Clock frequency
1MHz
Active edge
Negative (falling)
Power Supplies
+5V
800mA typ. / 1100mA max.
+12V
10mA max.