Model 6220/6221 Reference Manual
SCPI Reference Tables 14-13
Return to
Section 14 topics
Table 14-7
Status command summary
Command
Description
Default
Sec
SCPI
STATus
Commands status registers:
Note 1
√
:MEASurement
Measurement event registers:
[:EVENt]?
Read the event register.
Note 2
:ENABle <NDN> or <NRf>
Program the enable register.
Note 3
:ENABle?
Read the enable register.
:CONDition?
Read the condition register.
:OPERation
Operation event registers:
√
[:EVENt]?
Read the event register.
Note 2
√
:ENABle <NDN> or <NRf>
Program the enable register.
Note 3
√
:ENABle?
Read the enable register.
√
:CONDition?
Read the condition register.
√
:QUEStionable
Questionable event registers:
√
[:EVENt]?
Read the event register.
Note 2
√
:ENABle <NDN> or <NRf>
Program the enable register.
Note 3
√
:ENABle?
Read the enable register.
√
:CONDition?
Read the condition register.
√
:PRESet
Return status registers to default states.
√
:QUEue
Read error queue:
√
[:NEXT]?
Read the most recent error message.
Note 4
√
:ENABle <list>
Specify error and status messages for error
queue: -999 to +999.
Note 5
√
:ENABle?
Read the enabled messages.
√
:DISable <list>
Specify error and status messages not to
be placed in error queue: -999 to +999.
√
:DISable?
Read the disabled messages.
√
:CLEar
Clears all messages from error queue.
Parameters:
<NDN>
= #Bxx…x
Binary format (each x = 1 or 0)
= #Hx
Hexadecimal format (x = 0 to FFFF)
= #Qx
Octal format (x = 0 to 177777)
<NRf>
= 0 to 65535
Decimal format
Notes:
1. Commands in this subsystem are not affected by *RST or SYSTem:PRESet. The effects of cycling power, *CLS
and STATus:PRESet are explained by the following notes.
2. Event registers — Power-up and *CLS clears all bits. STATus:PRESet has no effect.
3. Enable registers — Power-up and STATus:PRESet clears all bits. *CLS has no effect.
4. Error queue — Power-up and *CLS empties the error queue. STATus:PRESet has no effect.
5. Error queue messages — Power-up enables error messages and disables status messages. *CLS and
STATus:PRESet have no effect.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
Содержание 6220
Страница 16: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...
Страница 24: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...
Страница 403: ...A Specifications Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...
Страница 453: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...