Model 2700 Multimeter/Switch System User’s Manual
Buffer
6-15
m.
CALCulate2:FORMat <name>
Select buffer statistic
CALCulate2:STATe ON | OFF
Control (on/off) buffer statistic
CALCulate2:IMMediate
Calculate data in buffer
CALCulate2:IMMediate?
Calculate and read result
CALCulate2:DATA?
Read result of statistic calculation
<name> = MINimum | MAXimum | MEAN | SDEViation | PKPK | NONE
After the selected buffer statistic is enabled, IMMediate or IMMediate? must be sent to
calculate the statistic from the data in the buffer. The CALCulate2:DATA? command does
not initiate a calculate operation. It simply returns the result of the last calculation. If new
data is stored in the buffer, you must again send IMMediate or IMMediate? to recalculate
the statistic from that new data.
NOTE
If the standard deviation calculation is being performed on a buffer that has
more than 1000 readings, the “CALCULATING” message will flash to indicate
that the Model 2700 is busy. While busy with the calculation, remote
programming commands will not execute.
NOTE
Use *OPC or *OPC? with CALC2:IMM and CALC2:IMM? when performing
the standard deviation calculation on a large buffer. See
on *OPC and *OPC?
Programming example
The following command sequence stores 20 readings in the buffer and then calculates the
mean for those readings. Note that after sending a query command, the Model 2700 must
be addressed to talk.
NOTE
The following example can be run from the KE2700 Instrument Driver using the
.
' Store readings:
TRAC:CLE:AUTO ON
' Enable buffer auto-clear.
TRAC:POIN 20
' Set buffer size to 20.
TRAC:FEED SENS
' Select raw readings for storage.
TRAC:FEED:CONT NEXT
' Start storage process.
TRAC:DATA?
' Request all stored readings.
' Calculate mean:
CALC2:FORM MEAN
' Select mean calculation.
CALC2:STAT ON
' Enable mean calculation.
CALC2:IMM?
' Perform calculation and request result.
Содержание 2700
Страница 3: ......
Страница 7: ......
Страница 197: ...5 24 Rel Math Ratio Channel Average dB Model 2700 Multimeter Switch System User s Manual...
Страница 213: ...6 16 Buffer Model 2700 Multimeter Switch System User s Manual...
Страница 289: ...9 18 Limits and Digital I O Model 2700 Multimeter Switch System User s Manual...
Страница 335: ...11 24 Status Structure Model 2700 Multimeter Switch System User s Manual...
Страница 336: ...12 CommonCommands...
Страница 344: ...13 SCPISignalOriented MeasurementCommands...
Страница 353: ...13 10 SCPI Signal Oriented Commands Model 2700 Multimeter Switch System User s Manual...
Страница 363: ...14 10 FORMat and Misc SYSTem Commands Model 2700 Multimeter Switch System User s Manual...
Страница 364: ...15 SCPIReferenceTables...
Страница 391: ...A 2 Specifications Model 2700 Multimeter Switch System User s Manual...
Страница 392: ...Model 2700 Multimeter Switch System User s Manual Specifications A 3...
Страница 393: ...A 4 Specifications Model 2700 Multimeter Switch System User s Manual...
Страница 394: ...Model 2700 Multimeter Switch System User s Manual Specifications A 5...
Страница 395: ...A 6 Specifications Model 2700 Multimeter Switch System User s Manual...
Страница 400: ...B Model7700ConnectionGuide...
Страница 411: ...B 12 Model 7700 Connection Guide Model 2700 Multimeter Switch System User s Manual...
Страница 412: ...C StatusandErrorMessages...
Страница 419: ...C 8 Status and Error Messages Model 2700 Multimeter Switch System User s Manual...
Страница 420: ...D SignalProcessing SequenceandDataFlow...
Страница 433: ...D 14 Signal Processing Sequence and Data Flow Model 2700 Multimeter Switch System User s Manual...
Страница 434: ...E MeasurementConsiderations...
Страница 443: ...E 10 Measurement Considerations Model 2700 Multimeter Switch System User s Manual...
Страница 454: ...G IEEE 488BusOverview...
Страница 469: ...G 16 IEEE 488 Bus Overview Model 2700 Multimeter Switch System User s Manual...
Страница 470: ...H KE2700InstrumentDriver Examples...
Страница 489: ...H 20 KE2700 Instrument Driver Examples Model 2700 Multimeter Switch System User s Manual...
Страница 499: ......