User Guide
GEO-Fence Alarm
Command: G
+
X
, Y,
Z,
xxx
M/KM
Example:
G
1
,
1
,
1
,
100
M
Notes:
No spaces in between.
X
=No. of Geo fence (1~3), user can set 3 Geo fences
Y
=0 means to turn off the function
Y
=1 means to turn on the function
Z
=1 means to set alarm when the tracker enters the preset area
Z
=0 means to set alarm when the tracker breaches the district
xxx
is the preset distance to the tracker’s original place, must be 3 digitals.
M means meters, KM means kilometers. The device will
send the message to the authorized numbers as “Geo fence alarm! +GPS info”
when it
enters
the area you set.
(User must set this function when the blue light is flashing rapidly.)
To turn off this function, please send
G1,0 or G2,0 or G3,0