background image

 

Manifold Electronic Gauge

 

Model: KC-100B 

Operation Manual

 

 

 

 

 

 

 

1

Содержание KC-100B

Страница 1: ...Manifold Electronic Gauge Model KC 100B Operation Manual 1 ...

Страница 2: ...al safety rule SAFETY INSTRUCTIONS Failure to follow the instructions listed below may cause personal injury z Read and understand all instructions prior to any operation z Do not remove any labels from the tool z Do not operate the tool with the presence of flammable explosive gases z Do not operate the laser tool around the children or allow children to operate the laser tool failure to do so wi...

Страница 3: ...r line is the current measuring result and the data of lower line is the memory computing result D M Memory input key Input the length area or volume into memory E READ On read key Press this key to start the tool and read the measured distance keep pressing this key and move the tool to read values dynamically F SET Clear Menu press this key to clear or return back to the menu to select length ar...

Страница 4: ...d surface z Keep pressing the READ key and move the tool to get the dynamical readings and the measured distance will be displayed on upper portion of the screen z Press the SET key and the READ key together to select the measuring unit as British measurement or metric system original measuring unit Metric measurement Tips A The measured object must be normatively hard surface and not be blocked b...

Страница 5: ...on of the screen z Repeat the steps above can continue accumulation Addition using M memory z Press the M key to save the first measured result and the M will appear on the display z Press the READ key for new measurement z Press the key to enter the addition mode and the will appear on the display z Press the RM key to recall previous measurement for the addition displayed on the bottom of the di...

Страница 6: ... will toggle back and forth between the length and width measurement on the upper portion of the screen Press SET key to clear the data on the portion of the screen then can begin the new calculation of area To choose measurement mode press SET key again Tips Press the SET key one by one will toggle back and forth between the length area and volume measurement If there are datum on the display fir...

Страница 7: ... calculation of a room volume z The length character L on the screen will blink showing length measurement will be taking Press READ key to take length measurement the result will be displayed on upper portion of screen Step 1 z The width character W on the screen will blink showing the next measurement to take Press READ key to take width measurement the result will be displayed on upper portion ...

Страница 8: ...first time measurement and the M icon will appear on LCD z Press SET key to clear the current displayed data then can begin the second time measurement and computation Follow step 1 to 3 under the volume section z After getting the calculated volume of second time press key to enter the addition mode A icon would appear on LCD z Press RM key to recall the first calculated volume for the addition T...

Страница 9: ...pear between the tool and the measured surface z When the measured surface is not smooth the measured surface should be smooth hard and of homogeneity z When the measuring environment is not good the temperature and humidity will affect the accuracy of measurement and take measurement under environment of no wind and temperature of the unit should be same with temperature of the circumstance espec...

Страница 10: ...re 0 to 40 Operating humidity 30 70 Storage environment 20 60 85 w o battery Size 142mm 70mm 40mm Weight About 110g w o battery WARRANTY The product is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase on the basis of providing relevant card Notice The warranty does not apply to the following conditions z Disassembling the laser tool ...

Отзывы: