11.6.27.2 Error 26-2 (emergency code 7305h)
Cause: Channel 1 cyclic, Np (distance coded): error, delta correction failed
Suggested steps:
Please check the wiring of the encoder, perhaps reduce the speed.
Encoder channel, cyclic
evaluation
l
Error during the cyclic evaluation of an
encoder channel 1.
l
In any case look at init outputs in the message
window of the DriveManager.
l
The most common cause of error is the wiring
to the encoder.
11.6.27.3 Error 26-3 (emergency code 7305h)
Cause: Channel 1 cyclic, Np (distance coded): error, calculated 'delta' is out of range
Suggested steps:
Please check the wiring of the encoder
Encoder channel, cyclic
evaluation
l
Error during the cyclic evaluation of an
encoder channel 1.
l
In any case look at init outputs in the message
window of the DriveManager.
l
The most common cause of error is the wiring
to the encoder.
11.6.28 Error 28: Encoder channel 3, cyclic process error
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
412
11 Alarms & warnings
11.6.28.1 Error 28-1 (emergency code 7307h)
Cause: Channel 3 cyclic, Np (distance coded): error, measured 'counter distance' is
out of range
Suggested steps:
Please check the wiring of the encoder
Encoder channel, cyclic
evaluation
l
Error during the cyclic evaluation of an
encoder channel 3.
l
In any case look at init outputs in the message
window of the DriveManager.
l
The most common cause of error is the wiring
to the encoder.
11.6.28.2 Error 28-2 (emergency code 7307h)
Cause: Channel 3 cyclic, Np (distance coded): error, delta correction failed
Suggested steps:
Please check the wiring of the encoder, perhaps reduce the speed.
Encoder channel, cyclic
evaluation
l
Error during the cyclic evaluation of an
encoder channel 3.
l
In any case look at init outputs in the message
window of the DriveManager.
l
The most common cause of error is the wiring
to the encoder.