![Keba ServoOne CM Series Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/keba/servoone-cm-series/servoone-cm-series_operation-manual_660467037.webp)
37
Electrical installation
Operation Manual ServoOne CM-L and ServoOne CM-A
ID no.: 1800.208B.1-00 Date: 03/2020
Electrical installation
SO CM-A.00L4.x
Des.
Term.
Specification
Connection
LINE FILTER
U
x
AC mains connection
x
3 x 230...480 V AC
x
Connection cross-section:
maximum 35 mm
2
x
ConnZK for LC filter
LC (T
emp)
LINE FILTER
SYNC
U
V
W
+ZK
V
W
+ZK
x
Connect cable shield to the shield connection
rail.
LC (Temp)
x
Connection for LC filter temperature monitoring
x
Cross-section: 0.14 - 1.5 mm
2
(AWG 24-16)
SYNC
L1
x
AC mains connection mains synchronisation
x
3 x 230-480 V AC
x
Connection cross-section: maximum 2.5 mm
2
L2
L3
x
Connect cable shield to the shield connection
rail.
Table 4.10
Specification, AC mains connection ServoOne CM-A SO CM-A.00L4.x
NOTE
The local regulations on cable protection are to be followed!
4.6.8
ServoOne CM-D: specification, LINE FILTER, SYNC and
LC (Temp) connections
The mains voltage (U, V, W) for power connection is connected to the connector LINE
FILTER. +ZK is connected to connZK on the LC filter. The mains voltage (L1,
L2, L3) for the synchronisation is connected to the connector SYNC. The temperature
sensor for the LC filter is connected to the terminal "LC (Temp)".
SO CM-D00L2.x
Des.
Term.
Specification
Connection
LINE FILTER
U
x
AC mains connection
x
3 x 230...480 V AC
x
Connection cross-section: maximum 16
mm
2
LC(T
emp)
V
W
x
Connect cable shield to the shield con-
nection rail.
LC (Temp)
x
Connection for LC filter temperature
monitoring
x
Cross-section: 0.14 - 1.5 mm
2
(AWG
24-16)
SYNC
L1
x
AC mains connection mains synchroni-
sation
x
3 x 230-480 V AC
x
Connection cross-section: maximum
2.5 mm
2
L2
L3
+ ZK -
x
ConnZK for LC filter
x
Connection cross-section: maximum
16 mm
2
MOTOR
U
x
Motor connection
x
Design of cross-section depending on the
motor power and cable length:
x
Connection cross-section: maximum
16 mm
2
V
W
MOTOR
TEMP
x
Cross-section: 0.14 - 1.5 mm
2
(AWG
24-16)
BRAKE
x
Cross-section: 0.14 - 1.5 mm
2
(AWG
24-16)
Table 4.11
Specification, power connections for mains connection ServoOne CM-D
Содержание ServoOne CM Series
Страница 64: ...64 Appendix Operation Manual ServoOne CM L and ServoOne CM A ID no 1800 208B 1 00 Date 03 2020 Appendix ...
Страница 68: ...68 Glossary Operation Manual ServoOne CM L and ServoOne CM A ID no 1800 208B 1 00 Date 03 2020 Glossary ...
Страница 69: ...69 Operation Manual ServoOne CM L and ServoOne CM A ID no 1800 208B 1 00 Date 03 2020 ...