8.2
KeTop Configuration Tool (ConfigTool)
The ConfigTool is used to calibrate the operating elements, to control the func-
tionality of the operating elements and to set start-up functions.
To activate the tool, select the following item:
Start
▶
Programs
▶
KeTop
▶
KeTop Configuration Tool
(or by double-click-
ing on the file „Configuration_Tool.exe“ in the Windows directory).
Information
The appearance of the Config tool depends on the operating elements in-
stalled in KeTop (the menus for override potentiometer, joystick and hand-
wheel are only displayed when the operating elements are installed in the
device).
After carrying out modifications on the configuration and quitting the program,
you can save all modifications in the registry. A window with the following
message and options appears:
Data has changed! Do you want to write the registry to the flash? Yes/No
With "No", the settings will not be stored therefore. They will get lost when the
KeTop is turned off.
"Yes" saves the calibration in the flash. The settings are preserved after a re-
start of the device. The device is blocked during the saving procedure (takes
approx. 10 s).
8.2.1
Calibration of Joystick
A number is displayed next to the slide bar. During calibration, this number
specifies the current value of the ADC (value range: 0..1024) and only con-
trols the function. After calibration, the number specifies the current value of
the joystick (value range: -15.. 0..+15 for each joystick axis).
This value is also the value the KeTop API function
KtpGetJoystickPos
supplies to the application.
KeTop - Specific Operating Instructions
© KEBA 2009
User's Manual V1.50
89