1.4.2
Not contained in this document
●
Mask description of the application
●
Software
1.5
Documentation for further reading
If certificates (e.g. UL certificate) are required they can be purchased from
KEBA on request.
1.6
Information about MD 2006/42/EC
1.6.1
Definition of terms
This user's manual corresponds to machinery directive 2006/42/EC.
To avoid ambiguity for users the following table shows the comparison of the
old terms of MD 98/37/EC and the new ones of MD 2006/42/EC.
This term replacement is also fulfilled in the corresponding standard
EN ISO 13850:2008.
98/37/EC
2006/42/EC
emergency switching off (chap. 1.2.4)
emergency stop (chap 1.2.2)
Within standard EN 60204-1 the following term has changed:
EN 60204-1:1997
EN 60204-1:2006
Enabling device
Enabling control device (chapter 10.9)
In this manual the new terms of MD 2006/42/EC are used.
1.6.2
Quantitative safety relevant specifications for emergency stop-button
and enabling control device
Emergency stop-button and enabling control device (Enabling device)
KEBA specifies a B
10d
-value. Other values (e.g. SIL, PL, Category)
cannot
be
specified by KEBA.
Explanation: KEBA solely delivers the control element, but no evaluation of the
element. The customer has to connect the emergency stop and the enabling
control device to his application on his own. Depending on the connection of
the emergency stop and the enabling control device to the machine the SIL-
or category and PL-value can be determined.
The B
10d
-value is declared in the manuals at chapter "Technical Data" ("Emer-
gency stop" respective "Enabling Control Device".