4 Commissioning
4.3.1 Pre-set solu-
tions
Pre-set solutions are complete parameter data sets which are provided to
handle a wide variety of typical application movement tasks.
Fig. 4.2
Initial commissioning
The position controller is automatically configured by loading a pre-set
solution into the random access memory (RAM). The parameters for
the control location of the drive controller,
• the reference source,
• the assignment of signal processing input and outputs and
• the type of control
are the focal points of the setting.
The use of a pre-set solution considerably simplifies and shortens the
commissioning of the positioning controller. By changing individual
parameters, the preset solutions can be adapted to the needs of the spe-
cific task. Pre-set solutions modified this way are stored in the unit as user
datasets. In this way, you can arrive more rapidly at your desired move-
ment solution.