3-32
Operating Instructions CDF3000
3 Installation
OSD03
OSD04
2
1
•
short-circuit proof
•
I
max
= 500 mA
•
internal signal delay time
≈
250µs
•
Terminal scan cycle = 1 ms
•
High-side driver
•
to control up to two motor holding brakes
yes
Safe stop
Note: For further information please refer also to the chapter
ISDSH
16
"Safe Standstill" request
•
Limit frequency 500 Hz
•
PLC-compatible
•
Switching level low/high: <4.8 V / >18 V
DC
•
I
max
at 24 V = typically 3 mA
•
R
IN
= 3 k
Ω
•
internal signal delay time
≈
100µs
•
Terminal scan cycle = 1 ms
yes
RSH
18
17
"Safe Standstill" feedback signal
•
Relay, 1 make contact
•
24 V / 0,2 A AC, utilization
category AC1, cos
ϕ
= 1
(resistive load)
•
30 V / 0,2 A DC, utilization
category DC1, cos
ϕ
= 1
(resistive load)
•
Operating delay approx. 10 ms
yes
Relay outputs
OSD05
20
19
•
24 V / 1 A AC, utilization
category AC1, cos
ϕ
= 1
•
30 V / 1 A DC, utilization
category DC1, cos
ϕ
= 1
•
Operating delay approx. 10 ms
yes
Des.
Termina
l
X2
Specification
floating
Table 3.13
Specification of control connections
X2:18
X2:17
X2:20
X2:19
Содержание CDF3000
Страница 1: ...Positioning controller Rated current 8 A Power supply 24 48 V DC CDF3000 Operation Manual...
Страница 12: ...Operating Instructions CDF3000...
Страница 16: ...1 4 Operating Instructions CDF3000 1 Safety...
Страница 54: ...3 34 Operating Instructions CDF3000 3 Installation...
Страница 78: ...4 24 Operating Instructions CDF3000 4 Commissioning...
Страница 84: ...5 6 Operating Instructions CDF3000 5 Troubleshooting...