![Keba CDF3000 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/keba/cdf3000/cdf3000_operation-manual_3828484046.webp)
3-26
Operating Instructions CDF3000
3 Installation
3.10.8 Wiring and
commissioning
For the "STO" function the positioning controllers are equipped with addi-
tional logic circuits and a feedback contact. The logic cuts the power sup-
ply to the pulse amplifiers to activate the power stage. In combination with
the controller enable "ENPO" the system uses two channels to prevent
the motor creating a torque.
The internal function of the unit and the connection for CDF3000 is shown
in Fig. 3.12.
Relay outputs: Feedback signal (normally open contact) "STO"
OSD02
(RSH)
X2-17
X2-18
•
Diagnosis STO, both tripping
channels active, one NO
contact with automatically
resetting circuit-breaker
(polyswitch)
•
25 V / 200 mA AC, utilization
category AC1
•
30 V / 200 mA DC, utilization
category DC1
•
Operating delay approx.
10 ms
•
3 x 10
6
switching cycles
yes
Voltage supply
Des.
Term.
Specification
floating
Note:
In the range > 5 V / < 18 V the performance of the inputs is undefined.
*OSSD: (Output Signal Switching Device) tested semiconductor outputs.
Test pulses are suppressed for a period of 300 µs.
Table 3.11
X2 terminal assignment CDF3000,SH
X2:18
X2:17
Содержание CDF3000
Страница 1: ...Positioning controller Rated current 8 A Power supply 24 48 V DC CDF3000 Operation Manual...
Страница 12: ...Operating Instructions CDF3000...
Страница 16: ...1 4 Operating Instructions CDF3000 1 Safety...
Страница 54: ...3 34 Operating Instructions CDF3000 3 Installation...
Страница 78: ...4 24 Operating Instructions CDF3000 4 Commissioning...
Страница 84: ...5 6 Operating Instructions CDF3000 5 Troubleshooting...