Operating Instructions CDF3000
3-25
3 Installation
DE
EN
FR
IT
ES
FR
3.10.7 Overview of
"STO" connec-
tions for CDF
The servocontroller CDF3000 offers a separate input for the "STO"
request, a facility to deactivate the restart inhibit and a separate relay
contact for feedback.
Des.
Term.
Specification
floating
Digital inputs
ISDSH
(STO)
X2-16
•
Request input STO = Low-level
•
OSSD support*
•
Switching level low/high: < 4.8 V / > 18 V
DC
•
I
max
= typically 3 mA (at 24 V)
•
U
In max
= 24 V +20%
•
R
In nom.
= 3 k
Ω
•
internal signal delay time
≈
2ms
•
Terminal scan cycle = 1 ms
yes
ENPO
(STO)
X2-12
•
Request input STO = Low-level
•
OSSD support*
•
Disable restart inhibit (STO) and
enable power stage = High level
•
Switching level low/high: < 4.8 V / > 18 V
DC
•
I
max
= typically 7.5 mA (at 24 V)
•
U
In max
= 24 V +20%
•
R
In nom.
= 3 k
Ω
•
internal signal delay time
≈
10 ms
•
Terminal scan cycle = 1 ms
yes
Note:
In the range > 5 V / < 18 V the performance of the inputs is undefined.
*OSSD: (Output Signal Switching Device) tested semiconductor outputs.
Test pulses are suppressed for a period of 300 µs.
Table 3.11
X2 terminal assignment CDF3000,SH
Содержание CDF3000
Страница 1: ...Positioning controller Rated current 8 A Power supply 24 48 V DC CDF3000 Operation Manual...
Страница 12: ...Operating Instructions CDF3000...
Страница 16: ...1 4 Operating Instructions CDF3000 1 Safety...
Страница 54: ...3 34 Operating Instructions CDF3000 3 Installation...
Страница 78: ...4 24 Operating Instructions CDF3000 4 Commissioning...
Страница 84: ...5 6 Operating Instructions CDF3000 5 Troubleshooting...