GB - 16
Operation of the Unit
5. Operation of the Unit
An operator is necessary as accessories for local or external (Option: cable 00.F5.0C0-1xxx) programming
of the frequency inverter KEB COMBIVERT. In order to avoid malfunctions the frequency inverter must be
brought into status nOP before plug-on/remove of the operator (open control release). During starting of the
frequency inverter it always starts with the last stored values/factory setting.
5.1 Operator
Digital operator with operation and display: Part No. 00.F5.060-1000
Interface operator additionally with serial interface: Part No. 00.F5.060-2000
START
FUNC.
SPEED
ENTER
F/R
STOP
C O M B I V E R T
X6C
X6D
X6B
Only use the operator interface for the serial data transfer to RS232/485.The
direct connection, PC to the inverter is only valid with a special cable
(HSP5
PartNo. 00.F5.0C0-0001), otherwise, it would lead to the destruction of the
PC-interface
!
5 4 3 2 1
9 8 7 6
Double function
keyboard
Status-/Error display
Normal "LED on"
Error "LED blinks"
Interface check
BUS-operation "LED on"
(only 00.F5.060-2000)
5-digit LED display
RS232/RS485
(only 00.F5.060-2000)
SUB-D 9 pole male
Housing (PE)
PC
F5-Operator
RS232-cable 3m
PC / Operator
Part No. 00.58.025-001D
HSP5 diagnostic interface
(only 00.F5.060-2000)
PIN
RS485
Signal
Meaning
1
-
-
reserved
2
-
TxD
transmission signal RS232
3
-
RxD
receive signal RS232
4
A‘
RxD-A receive signal A RS485
5
B‘
RxD-B
receive signal B RS485
6
-
VP
voltage supply plus +5 V (Imax=10 mA)
7
C/C‘
DGND
data reference potential
8
A
TxD-A
transmission signal A RS485
9
B
TxD-B
transmission signal B RS485
SUB-D 9 pole female