3.1.2 Mechanical ambient conditions
Storage
Standard
Class
Descriptions
Vibration limits
1M3
Vibration amplitude 3.0 mm (2…9 Hz)
Acceleration amplitude 10 m/s² (9…200 Hz)
–
Railway
–
–
Shock limits
1M3
100 m/s²; 11 ms
Transport
Standard
Class
Descriptions
Vibration limits
2M1
Vibration amplitude 3.5 mm (2…9 Hz)
Acceleration amplitude 10 m/s² (9…200 Hz)
(acceleration amplitude 15 m/s² (200...500 Hz))
1)
–
Railway
–
–
Shock limits
2M1
100 m/s²; 11 ms
Operation
Standard
Class
Descriptions
Vibration limits
3M4
Vibration amplitude 3.0 mm (2…9 Hz)
Acceleration amplitude 10 m/s² (9…200 Hz)
–
Vibration amplitude 0.075 mm (10…57 Hz)
Acceleration amplitude 10 m/s² (57…150 Hz)
–
Railway
–
–
Shock limits
3M4
100 m/s²; 11 ms
Table 3:
Mechanical ambient conditions
1)
Not tested.
3.1.3 Chemical / mechanical active substances
Storage
Standard
Class
Descriptions
Contamination
Gases
1C2
–
Solids
1S2
–
Transport
Standard
Class
Descriptions
Contamination
Gases
2C2
–
Solids
2S2
–
Operation
Standard
Class
Descriptions
Contamination
Gases
3C2
–
Solids
3S2
–
Table 4:
Chemical / mechanical active substances
27