TecHNIcAL DATA G6 400V cLASS
3.3 Technical data G6 400V class
Unit size
07
09
10
Housing
A
Phases
3
Rated apparent output power
S
out
/ kVA
1.8
2.8
4.0
Max. rated motor power
P
mot
/ kW
0.75
1.5
2.2
Rated output current
I
N
/ A
2.6
4.1
5.8
Rated output current UL
I
N_UL
/ A
1.8
3.4
4.8
Short time current limit
1)
I
HSR
/ %
180
Overcurrent
1)
I
OC
/ %
216
Maximum current at 0Hz / corner frequency
f
d
at
f
S
= 4 kHz
1)
I
f0/Ifd
/ %
100 / 180
100 / 180
100 / 180
Maximum current at 0Hz / corner frequency
f
d
at
f
S
= 8 kHz
1)
I
f0/Ifd
/ %
100 / 180
100 / 150
85 / 150
Corner frequency
f
d
/ Hz
6
Rated input current
I
in
/ A
3.6
6.0
8.0
Rated input current UL
I
in_UL
/ A
2.5
4.8
7.0
Rated input current DC
2)
I
in_dc
/ A
1.9
3.7
5.2
Rated input current UL DC
2)
I
in_UL_dc
/ A
1.6
3.0
4.2
Max. permissible main fuse type gG
I
_max
/ A
16
16
16
Rated switching frequency
3)
f
SN
/ kHz
8
4
4
Max. switching frequency
3)
f
S_max
/ kHz
8
8
8
Power dissipation at nominal operating
4)
P
D
/ W
45
49
70
Power dissipation standby (no control release)
4)
P
D_nop
/ W
10
Max. heat sink temperature
T
HS
/ °C
90
Temperature for derating the switching frequency
5)
T
dr
/ °C
85
Temperature for uprating the switching frequency
5)
T
ur
/ °C
80
Min. braking resistor
R
B_min
/ Ω
120
Max. braking current
I
B_max
/ A
7
Rated input voltage
U
N
/ V
400 (UL: 480)
Input voltage range
U
in
/ V
340…528 ±0
Mains frequency
f
N
/ Hz
50 / 60 ±2
Rated input voltage DC
U
N_dc
/ V
565 (UL: 680)
Input voltage range at DC supply
U
in_dc
/ V
480…746 ±0
DC switch-off level „Error! Underpotential“
U
UP_dc
/ V
240
Switching level DC braking resistor
U
B_dc
/ V
780
DC switch-off level „Error! Overpotential“
U
OP_dc
/ V
840
Output voltage
6)
U
out
/ V
3 x 0…
U
in
Output voltage at DC devices
6)
U
out_dc
/ V
3 x 0…
U
in_dc
/ √2
Output frequency (depending on the operating mode)
3)
f
out
/ Hz
0…400 (
f
s
= 4 kHz)
0…599 (
f
s
= 8 kHz)
Insulation resistance @
U
dc
= 500 V
R
iso
/ MΩ
10
Minimum waiting period between two switch-on procedures
t
/ min
5
Table 8:
Technical data 400V class
1)
The values refer percentage to the rated output current I
N
.
2)
The values resulting from rated operation with B6 rectifier circuit and mains choke 4% U
K.
3)
The output frequency is to be limited in such a way that it does not exceed 1/10 of the switching frequency.
4)
Rated operation corresponds to U
N
= 400 V; f
SN
; f
out
= 50 Hz (typically value).
5)
On reaching the temperature T
dr
the switching frequency is step down. The switching frequency is increased again on cooling down
to temperature T
ur
.
6)
The voltage at the motor is dependent on the series-connected units and on the control method
,
=>
„Calculation of the motor voltage“
.
The technical data are for 2/4-pole standard motors. With other pole numbers
the drive converter must be dimensioned onto the rated motor current. Contact
KEB for special or medium frequency motors.