10.1.9.8
Status and control word
The control word is used for the status control of the inverter via bus. The actual state of the inverter can be
read out with the status word.
The control word low is bit-coded designed as follows.
SY.50: Control word low
Bit
Function
Value
Description
0
Control re-
lease
1: ST
This bit is only effective if di.01 „select signal source“ bit 0 is
set. Then the AND operation of this bit with di.02 „digital input
setting“ bit 0 is valid.
1
Automatic
2: RST
An error reset is executed when changing from not activated (0)
to activated (2).
2
Start / stop
0: Stop
Direction of rotation release or the „start “(„run “) command can
be given via the control word, if oP.01 „rotation source“ contains
the values 6, 8, 9 or 10.
4: Start
3
Clockwise /
counter clock-
wise rotation
0: Clockwise
rotation
If oP.01 „rotation source“ contains the values 8 or 9, the direction
of rotation is preset via this bit.
8: Counter-clock-
wise rotation
4...6
Parameter set
0: Set 0
Selection of the active parameter set, if in Fr.02 „parameter set
source“ the value „5: control word (SY.50)“ is programmed
16: Set 1
32: Set 2
48: Set 3
64: Set 4
80: Set 5
96: Set 6
112: Set 7
7
reserved
8
Fast stop on
/ off
256: Fast stop
Releases fast stop (OR operation with further fast stop sources).
9
Start approach
to reference
point
512: Start ap-
proach to refe-
rence point
Change of not activated (0) to activated (512) starts approach
to reference point.
10
Start Positio-
ning
1024: Start Posi-
tioning
Change of not activated (0) to activated (1024) starts the posi-
tioning.
11
Interruption
2048: Interruption
Change of not activated (0) to activated (2048) stops the positio-
ning (drive is stopped with ramp according to positioning profile)
12, 13
Operating
mode
0: off
Selection of the operating mode via the control word.
Only valid if in PS.00 „posi/syn mode“ in bits 0..2 value „7: via
control word“ is programmed)
4096: Synchro-
nous running
8192: positioning
12288: Contou-
ring control
14, 15 reserved
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...