Special functions
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.15 - 27
7
PID controller KP (cn.04)
Determines the proportional gain factor in the range of 0,00...250,00.
PID controller KI (cn.05)
Determines the integral gain factor in the range of 0.000...30.000.
PID controller KD (cn.06)
Determines the differential gain factor in the range of 0.000...250.00.
PID positive limit (cn.07), PID negative limit (cn.08)
The maximum positive manipulated variable in the range of -400.0...400.0 % is specified with cn.07, the maxi
-
mum negative manipulated variable in the range of -400.0...400.0 % with cn.08.
PID fading time (cn.09)
Thereby the controller intervention can be linerarly increased at the start or linearly decreased at the reset of
fading. The time refers to 100% controller output value. If an input is programmed to „fade in reset (cn.13)“, the
fade in is counted down when the input is active and counted up when the input is inactive.
If „- 0.01“ is adjusted fade in is calculated in accordance with the following formula:
Fade in factor = f
setting
(ru.02) / max. setpoint (oP.10/11)
The function is only active if the technology controller is used as process controller (cS.00 Bit 0...2 = 1). The
fading time is 0 if it is used as setpoint controller.
PID reset condition (cn.10)
The reset condition of the PID controller can be preset via cn.10. Simple speed controls for both directions of
rotation can be realized thereby.
cn.10: PID reset condition
Value
Explanation
0
PID controller is not reset
1
PID controller = 0 (constantly reset)
2
PID controller is reset if the modulation is off
Value „2“ must be adjusted for speed control in order that the I-component of the controller is reset at LS or nOP.
Value „1“serves primary for the start-up, in order to reset the controller manually.
Reset of the controller via digital inputs (cn.11...13)
The total controller, the I-component, as well as the controller fading can be reset via the digital inputs. The
fade-in time is valid at reset of fading. For that the decimal value of the corresponding inputs must be entered
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...