Page 7.15 - 14
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Special functions
7.15.5.2
Monitoring of the brake control
Pn.43 "min. load brake control"
Further brake control can be activated with Pn.43 "min. load brake control".
For the monitoring of the utilization acceptance through the inverter a minimal utilization level can be adjusted
in this parameter.
If the brake is to be opened on start at the end of the pre-magnetising time (Pn.35), the load factor may not be
smaller than the adjusted level. Otherwise error E. br is triggered. Reaching the hardware current limit during
this phase also triggers error E.br. The current is monitored only at this time (directly before the opening of the
brake).
The monitoring is deactivated when Pn.43 is set to 0.
Pn.42 "brake check input selection"
The brake must always be closed between the end of the brake closing time (Pn.40) and the beginning of the
break release time (Pn.36). E.br is triggered if the input becomes (or is) active during this phase.
Similarly, from the end of the brake opening period (Pn.36) to the end of the brake delay time (Pn.39), the brake
must always remain ventilated. If the input becomes (or is) inactive in this phase, E.br is also triggered.
With this input, e.g., a protection monitoring could be executed.
7.15.5.3
Sequence of the brake control
The sequence of the brake control is defined by five times, two for the opening and three for the closing of the
brake.
open brake
The opening of the brake is started when the control release is closed and the command to start the drive is
received.
In vector controlled operation, this is the activation of the direction of rotation, the setpoint speed has no effect.
That means: the brake is opened as well on setting the speed setpoint value = 0.
During positioning, the opening of the brake is triggered, e.g., by a "Start positioning" or a "Start approach to
reference point" command
•
Pn.35: premagnetising time
The pre-magnetisation time serves to build up a holding torque to minimise the "stall out" of the drive
during ventilation of the brake.
The adjustment of this time and the brake control start ref. (Pn.37) is depending on the mode
(v/f-characteristic controlled, vector controlled, etc.) and is described in the items 7.15.5.4 and 7.15.5.5.
•
Pn.36: Brake release time
With begin of the brake release time, the signal to open the brake is issued.
During brake release time when the brake is mechanically released, the speed set value (ru.01) is not yet
stored, but the brake control starting value (Pn.37) is still maintained. For vector controlled systems, Pn.37
must contain the value 0 rpm for synchronous as well as for asynchronous motors.
close brake
The closing of the brake is triggered by disabling the direction of rotation (speed control), reaching of the target
position (positioning), or switching off the modulation (opening of the control release or error).
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...