Settings:
●
The drive shall stop at each position to allow processing of the workpiece, until the external control
gives the signal to continue, i.e., "start positioning". The external signal occurs via input I3. The drive
shall signal the control through an output that it has reached target with an accuracy of 10 increments,
so that the processing can begin.
●
Let the position at which the workpiece starts have the value 0.
●
Driving to this position (whether after "power on“, after error or as part of the positioning process) can
always occur at maximum speed = 1500 rpm.
●
The first stop shall be at position 100,000. The profile speed up to that point shall be 1000 rpm.
●
The second stop shall be at position 200,000. The profile speed up to that position shall again be 1000
rpm.
●
After that, the drive shall return to its starting position with maximally 1500 rpm.
Adjustments:
● PS.00:
PS.00: Posi / synchronous mode
Bit
Meaning
Value
Explanation
0...2
Posi / synchro-
nous mode
5: Posi mode
Activation of the positioning mode
4
Positioning /
target speed
0: PS.25 /
PS.25
The maximum profile speed is set via
PS.25 "Index / speed".
All other bits can remain at the factory settings for this example and are explained in the following chapters.
●
Block 0 defines the start position
→
PS.28 = 0
●
Input I3 serves as "start positioning"
→
PS.29 = 64: I3 (X2A.12)
●
block 0
→
PS.23: Index / selection = 0
Position = 0
→
PS.24: Index / position = 0
Permitted max. speed = 1500 rpm
→
PS.25 = 1500 rpm
next positioning step defined in block 1
→
PS.26 = 1
no automatic starting of the drilling process, but waiting for "start position" command, i.e. "continuati-
on of the profile processing“ = 0: no and „position setting“ = 0: absolute
→
PS.27 = 0: no + absolute
●
block 1
→
PS.23: Index / selection = 1
Position = first stopping point
→
PS.24: Index / position = 100.000
speed up to the first stopping point
→
PS.25 = 1000 rpm
next positioning step defined in block 2
→
PS.26 = 2
Stop at the position, i.e., "continuation of the profile proces
-
sing" = 0:no / "position setpoint" = 0:absolute
→
PS.27 = 0: no + absolute
●
block 2
→
PS.23: Index / selection = 2
Posi- and synchronous operating
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.12 - 45
7
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...