PS.24
index / position
(=
ru.61
) target position
PS.25
Index / speed
in % of oP.10
oP.28..31
Acceleration /
deceleration time
oP.32..35 and oP.70..73
S-curve times
(jerk limitation)
ru.54
actual position
oP.14
abs. max. reference
forward
Profile calculation
ru.61: target position [Inc]
ru.56: set position [Inc]
profile speed [rpm]
Profile
speed
PS.09
pos
Posi/synchronous
ru.56
Set position
ru.02
display
output display
(
setpoint speed for
speed controller)
PS.06..PS.08
Position
controller
7.12.4.3
Posi mode / premise
To activate the positioning module, the following conditions must be met:
-
Start-up in the vector controlled operation must be completed successfully.
-
The position feedback must be defined (in
PS.01 "master source", select the appropriate encoder
interface and make the adjustments required for the encoder type in the Ec-parameters).
-
An input for the activation of the positioning module must be defined (
PS.02 "pos/syn input select").
-
If hardware limit switches are to be used, two inputs must be programmed with the functions „32:
forward“ and „64: backward“ and wired with the hardware limit switches. Additionally, the protec-
tion function in Pn.07 "proh. rot. stopping mode" must be activated.
-
If an absolute position reference is required, a reference point switch must be wired and an ap-
proach to reference point must be executed or an absolute encoder for the position feedback must
be used.
-
It must be defined how the positioning is to be started (e.g., digital input, selectable via
PS.29:
"start positioning input selection" or control word).
-
The value for the position controller (PS.06 "KP pos/syn") must be set to a small value for the start-
up to avoid vibrations. If the basic start-up has completed successfully, the position controller must
be adjusted application-specific.
Note: after activation of the positioning module, the drive remains in vector controlled operation until the first
"start positioning" command has been executed. The behavior during this phase is determined with PS.00 bit
13.
Posi- and synchronous operating
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.12 - 29
7
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...