Page 7.12 - 8
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Posi- and synchronous operating
7.12.2.2
Approach to reference point / stopping point
PS.14 determines on which side of the reference point switch the drive is positioned after the approach to re-
ference point. Even if, after the free driving of the reference switch, positioning is to occur based on the zero
signal, "stopping point " determines if the first null signal is to be driven on at the right or left of the reference
switch.
The adjustment is only considered if the reference point switch serves not simultaneously as limit switch.
PS.14: Mode of position reference
Bit
Meaning
Value
Explanation
3
Stopping
point
0: right
Stop on the right side of the reference point switch
8: left
Stop on the left side of the reference point switch
7.12.2.3
Approach to reference point / stop at zero signal
An approach to reference point that depends only on the initiator signal of the reference point switch is insuf-
ficiently precise for many applications. Therefore, the possibility exists to couple the reference point with the
marker pulse of the encoder.
To that end, positioning after the free driving of the reference switch is done on the marker pulse of the encoder
and the current actual position=marker pulse is then overwritten with the reference point value.
With "stop at null signal= 4: yes" this function is activated.
Additionally, two monitoring functions can be switched in with bit 4 "error if no zero signal" and bit 8 "Verify zero
signal". These are only active if "stop at null signal= yes" is programmed.
PS.14: Mode of position reference
Bit
Meaning
Value
Explanation
2
Stop at zero
signal
0: no
The drive stops directly after free driving of the reference point switch.
4: yes
The drive positions on the null signal of the encoder after free driving of
the reference point switch at the free drive-speed. If during the drive to the
reference switch no null signal was received, the behaviour of the drive is
determined by bit 4 "error if no zero signal".
4
Error, if no zero
signal
0: off
If, during the reference point search, no null signal is recognised, the drive
rotates maximally another two revolutions at the free drive-speed to locate
the null signal. If the null signal is found, the drive reverses and drives
back to the reference point switch. Positioning on the null signal is execut-
ed after that.
If no null signal is recognised during the null signal search, the inverter
reports "error! encoder 1" or "Error! Encoder 2" (E.EnC1 respectively
E.EnC2)
16: on
If no zero signal is recognized during searching for the reference point
switch (i.e. if the reference switch is reached before the encoder sends
the first marker pulse), the inverter immediately indicates „Error! encoder
1" or "Error! encoder 2“ (E.EnC1 or E.EnC2).
8
Examine the
zero signal
0: off
no examination of the position of the null signal
256: on
The distance from switch to null signal is examined after driving free of
the reference point switch. If the zero signal does not lie within a range
of ¼ to ¾ revolution, „Error! encoder 1" or "Error! encoder 2“ (E.EnC) is
released.
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...