Speed measurement
7.11.8.2
Gear factor / analog setting
The gear factor numerator (Ec.04 and Ec.14, respectively) can be changed via the analog parameter setting
(see chapter 7.15.9).
Example:
The target is to be able to adjust the gear factor for encoder channel 2 between 0.9 and 1.1.
Gear factor denominator is chosen as 1000.
The gear factor numerator must also be settable to between 900 and 1100.
The analog setting shall be done through the Aux-input
=> An.53 Analog parameter setting source = 0: Aux input (ru.53)
The target of the setting is Ec.14 gear factor channel 2 numerator (bus address 100Eh)
=> An.54 Analog parameter setting destination = 100Eh
For an analog value of 0%, one should have gear factor numerator = 1000
=> An.55 Analog parameter setting offset = 1000
For an analog value of 100%, the gear factor numerator should be 1100
=> An.56 Analog parameter setting max. value = 1100
With this setting, a gear factor of 0.9 to 1.1 can be set with an Aux value of -100%...100%.
7.11.8.3
Gear factor / set-programming
The gear factor is generally not set-programmable.
There is a workaround in case the application needs a set-dependent gear factor.
One uses the option of analogously setting the gear factor for this purpose. As the source for the analog para-
meter setting, not an analog input but the motor potentiometer
value is selected, which can be specified set-
dependently.
Example:
In set 0, the gear factor should have the value 0.5, in set 1, the value 1, and in set 2, the value 1.5. Gear factor
denominator is chosen as 1000. The gear factor numerator must therefore be: in set 0 = 500, in set 1 = 1000,
and in set 2 = 1500.
The analog setting should be done by motor potentiometer
=> An.53 Analog parameter setting source = 1: Motor potentiometer (ru.37)
The target of the setting is Ec.14 gear factor channel 2 numerator (bus address 100E hex)
=> An.54 Analog parameter setting destination = 100Eh
The value range is symmetrical around 1000 (+/- 500)
=> An.55 Analog parameter setting offset = 1000
The maximum value for the gear factor numerator should be 1500
=> An.56 Analog parameter setting max. value = 1500
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...