Page 3.1-6
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Control Units
3.1.5 Aux-function (An.30)
The A-servo has only one analog input, the Aux-function can be used also with other input values (e.g. PI con-
troller output, motorpoti).
3.1.6 Voltage input / external power supply
The supply of the control circuit through an external voltage source keeps the control in operational condition
even if the power stage is switched off. To prevent undefined conditions at external power supply the basic
procedure is to first switch on the power supply and after that the inverter.
3.2 Control circuit A-servo
3.2.1 Terminal strip X2A
Tightening torque 0.22…0.25 Nm (2 lb inches).
Use shielded/drilled cables
Lay shield on one side of the inverter onto earth
potential
No NPN control is possible at A-servo!
X2A
1 2 5 7 8 10 11 12 13
24 25 26
16 18 19 21 22
PIN
Function
Name
Description
1
+ Set Value input 1
AN1+
Difference voltage input
0…±10 V DC ^
0…±maximum speed, Ri = 55 kΩ
2
- Set Value input 1
AN1-
5
Analog output
an
OUT1
Programmable analog output 0…±10 V DC/ 5 mA. Function is de-
fined by the machine builder
7
+10V output
CRF
Reference voltage output for set value potentiometer (+10 V DC /
max. 4 mA)
8
Analog Mass
COM
Mass for analog in- and outputs
10
Progr. input 1
I1
The function of the programmable inputs is defined by the machine
builder.
Switching voltage 13…30 V DC ±0 % smoothed
Ri=2.1 kΩ
11
Progr. input 2
I2
12
Progr. input 3
I3
13
Progr. input 4
I4
16
Supply voltage
Driver circuit
ST
Supply of the driver circuit
This input must be supplied with an external voltage of 20…30 V DC
±0 % / 0.2 A (U
BR
max. 3.6 Vss). An error reset is executed when
switching off this voltage
18
Transistor Output 1
O1
Programmable digital outputs
Load capacity for both outputs maximum 50 mA.
Function is defined by the machine builder
19
Transistor Output 2
O2
21
Supply voltage
Control board
Uin
Voltage supply of the control board
This input must be supplied with an external voltage of 20…30 V DC
±0 % / 0.8 A (U
BR
max. 3.6 Vss). Due to the separate supply the
control can be further operated also when the driver / power unit is
switched off.
22
Digital Mass
0 V
Potential for digital in-/outputs
Relay 1
Programmable relay output (CP.33)
Load capacity max. 30 V DC / 0.01…1 A
Function is defined by the machine builder
24
No contact
RLA
25
(NC contact)
RLB
26
Switching contact
RLC
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...