Page 7.5 - 10
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Motor data and controller adjustments of the asynchronous motor
7.5.1.7.4
Adjustment of the slip compensation (cS.00, cS.01, cS.04, cS.06, cS.09)
The integrated speed controller is used at cS.00 = 2 for slip compensation. The rotor speed calculated from the
motor model is selected as the actual controller value by cS.01 = 2.
The slip compensation can be configured with bits 3-6 in cS.00.
cS.00: Controller configuration
Bit
Meaning
Value
Explanation
3
Control mode
0
Change of direction of rotation via the controller not
possible
8
Change of direction of rotation via the controller pos-
sible
4
0
no controller intervention for controller setpoint = 0 min
-1
16
controller intervention even for controller setpoint = 0
min
-1
5
0
no breakdown slip limit
32
breakdown slip limit (rated slip x dr.09)
6
0
default slip compensation
64
improved slip compensation (cS.03)
cS.01: Actual source
Value
Explanation
0
Encoder interface channel 1, only reasonable for closed-loop
operation
1
Encoder interface channel 2, only reasonable for closed-loop
operation
2
calculated rotor speed
cS.04 Settings Limit
0…4000 rpm x resolution factor (dependent on ud.02)
Default: 750 rpm x resolution factor
The speed limit determines the maximum controller intervention.
cS.06 KP speed, cs.09 KI speed
0…32767, default 300(KP), 100(KI)
Proportional and/or integral factor of the speed controller.
ATTENTION! These parameters must be adjusted before activation of the slip compensation. The default va-
lues are optimised for closed-loop operation.
This adaption is carried out with the motor adaption (see chapter 7.5.1.7.3), and only a fine adjustment is ne
-
cessary.
7.5.1.7.5
Improved slip compensation (cS.00 Bit 6 = 64, cS.03)
During the standard slip compensation, the slip is proportional calculated from the effective current. This calcu-
lation becomes imprecise above the nominal setpoint and in generatoric operation.
For the improved slip compensation, the slip calculation during motor operation above the nominal setpoint is
approximated to the real M/n-characteristic with a parabolic function. Greater inaccuracies will then occur only
above twice the rated torque.
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...